background image

NetSure™ 

Battery Rack System (+24 VDC) 

Installation Manual (Section 6044), Revision E 

Specification Number:  588810100, 588810200 
Model Number:  24BA1200-19, 24BA1200-23 

 

Summary of Contents for 24BA1200-19

Page 1: ...NetSure Battery Rack System 24 VDC Installation Manual Section 6044 Revision E Specification Number 588810100 588810200 Model Number 24BA1200 19 24BA1200 23...

Page 2: ...ls and materials to be used in performing procedures not specifically described in this document This document may contain confidential and or proprietary information of Vertiv Group Corporation and i...

Page 3: ...ack 9 Making Electrical Connections 11 Observe the Following Admonishment 11 Wiring Considerations 11 Relay Rack Grounding Connection Frame Ground 11 Battery Disconnect Circuit Breakers if furnished E...

Page 4: ...not avoided ANSI OSHA This admonition is not used for situations that pose a risk only to equipment data or service even if such use appears to be permitted in some of the applicable standards OSHA A...

Page 5: ...heck for voltage with both AC and DC voltmeters prior to making contact d Wear eye protection e Use certified and well maintained insulated tools Use double insulated tools appropriately rated for the...

Page 6: ...ately rated for the work to be performed Ensure that wrenches with more than one working end have only one end exposed Do not lay tools or metal parts on top of batteries Disconnect charging source pr...

Page 7: ...on this equipment An appropriate flash protection boundary analysis should be done determine the hazard risk category and to select proper PPE This product is intended only for installation in a Restr...

Page 8: ...Vertiv NetSure Battery Rack System 24 VDC Installation Manual Section 6044 Rev E 8 This Page Intentionally Blank...

Page 9: ...cedure was read When installation is done ensure that each block in this list has been checked Relay Rack Mounted to Floor Relay Rack Grounding Connection Made Battery Disconnect Circuit Breakers if f...

Page 10: ...tiv NetSure Battery Rack System 24 VDC Installation Manual Section 6044 Rev E 10 Figure 1 Relay Rack Floor Mounting Hole Dimensions 588810100 Figure 2 Relay Rack Floor Mounting Hole Dimensions 5888102...

Page 11: ...trical Code and applicable local codes Relay Rack Grounding Connection Frame Ground For relay rack grounding requirements refer to the National Electrical Code applicable local codes and your specific...

Page 12: ...r is in the OFF position resistive battery is provided at terminal 1 of J3 on the alarm card Also relay contacts open between terminals 2 and 3 of J3 and close between terminals 3 and 4 of J3 located...

Page 13: ...ovided two hole lugs with 1 inch centers Customer must provide lug mounting bolts washers and additional hardware Refer to Figure 5 Procedure 1 Remove front and rear protective covers ALERT Observe co...

Page 14: ...Front Front 24V Battery Busbar GND RTN Busbar 24V Battery Busbar GND RTN Busbar 24V Battery and GND RTN Busbars 24V Battery and GND RTN Busbars Customer Battery Cable Connections to Pwr Sys Customer...

Page 15: ...te batteries of different lengths A correctly oriented bracket will fit snuggly against the batteries Spec No 588810200 Only If your batteries require the alternate bracket orientation shown in Detail...

Page 16: ...o and to Observe correct polarity Refer to Figure 6 or Figure 7 Torque battery connections to battery manufacturer s recommendations 8 Repeat steps 1 through 7 for any remaining battery trays 9 If Bat...

Page 17: ...attery to these Two Terminals Connect Link Furnished with Battery to these Two Terminals If trays are equipped with circuit breakers TURN OFF ALL circuit breakers before installing and connecting any...

Page 18: ...minals Connect Link Furnished with Battery to these Two Terminals If trays are equipped with circuit breakers TURN OFF ALL circuit breakers before installing and connecting any batteries Connect POS B...

Page 19: ...Kit Battery Cover Assembled to Existing Front Battery Bracket Rear View Kit Battery Cover Assembled to Existing Front Battery Bracket Front View Use kit supplied hardware Procedure 1 Install batteries...

Page 20: ...sure all furnished protective covers are installed If provided ensure all battery circuit breakers are placed in the ON position NOTE Circuit breakers are provided with lockout tagout capability Refer...

Page 21: ...Vertiv NetSure Battery Rack System 24 VDC Installation Manual Section 6044 Rev E 21 This Page Intentionally Blank...

Page 22: ...VertivCo com Vertiv Headquarters 1050 Dearborn Drive Columbus OH 43085 USA Section 6044 RE 10 17...