User Guide
Vertilon Corporation, 66 Tadmuck Road, Westford, MA 01886
/
Tel: (978) 692-7070
Fax: (978) 692-7010
www.vertilon.com
SIB864
8 x 8 SiPM Sensor Interface Board
Ketek PA3325-WB-0808
Page 1: ...User Guide Vertilon Corporation 66 Tadmuck Road Westford MA 01886 Tel 978 692 7070 Fax 978 692 7010 www vertilon com SIB864 8 x 8 SiPM Sensor Interface Board Ketek PA3325 WB 0808...
Page 2: ...thout limitation loss of use loss or alteration of data delays lost profits or savings arising from the use of this document or the product which it accompanies Vertilon reserves the right to change t...
Page 3: ...User Guide 3 Vertilon Corporation 66 Tadmuck Road Westford MA 01886 Tel 978 692 7070 info vertilon com www vertilon com...
Page 4: ...cautions 6 Product Overview 7 Specifications 9 Typical Radiation Detection Setup 10 PA3325 WB 0808 Detector Mounting 10 Detector Channels 11 Detector Channel Mapping 12 High Voltage Interface 12 Pream...
Page 5: ...igure 5 SIPM High Voltage Interface Circuit 12 Figure 6 SIB864 Dialog Box 13 Figure 7 Leading Edge Discriminator Timing 14 Figure 8 PCB Top and Bottom Views 15 Figure 9 Top Component Locations and Fun...
Page 6: ...n damage to the SIB864 or the SIPM array Operate Inputs within Specified Range To avoid electric shock fire hazard or damage to the product do not apply a voltage to any input outside of its specified...
Page 7: ...ected on the PA3325 WB 0808 device The trigger output is typically connected to the trigger input of the PhotoniQ data acquisition system where it is used to initiate the collection of the energy sign...
Page 8: ...0808 SENSOR INTERFACE BOARD KETEK PA3325 WB 0808 8 X 8 SiPM ARRAY A1 P1 P2 P3 P31 P32 P35 P63 P64 P34 P33 SiPM CATHODE OUTPUTS J2 SIB CONNECTOR CONTROL STATUS J1 SIB CONNECTOR TEMPERATURE SENSOR CONTR...
Page 9: ...4 Transimpedance High Gain Rin 750 Nominal Baseline Voltage 2 50 V Signal Range 0 50 2 50 V Maximum signal amplitude is 2 0V below baseline Note these levels are halved when the preamplifier SMB outpu...
Page 10: ...e array The energy level threshold for the radiation event is set by the user through the PhotoniQ graphical user interface Charge signals from the 64 cathodes of the PA3325 WB 0808 device are acquire...
Page 11: ...Q utilizes DC coupled high speed transimpedance amplifiers that maintain a DC bias voltage of 0 250 volts on each of its inputs Because the PA3325 WB 0808 is configured on the SIB864 as a common anode...
Page 12: ...G1 G2 G8 49 50 56 H1 H2 H8 57 58 64 Table 2 SIPM Array Channel Mapping High Voltage Interface The SIB864 employs the interface circuit shown below between the high voltage input connector J7 and the c...
Page 13: ...e SIB864 The preamplifier generates a voltage signal in response to the current signal on its input from any of the 64 SIPMs in the array This voltage signal is available on an SMB output connector on...
Page 14: ...elay td from when the pulse first crosses the threshold Vth The discriminator switches back to a logic low when the pulse crosses the threshold from the opposite direction as it returns back to the ba...
Page 15: ...ottom Views 1 PA3325 WB 0808 Sockets 7 Preamplifier Output J6 2 SIB Connector Channels 1 to 32 J1 8 Trigger Output J4 3 SIB Connector Channels 33 to 64 J2 9 External Input Unused J5 4 Configuration Sw...
Page 16: ...8 692 7070 info vertilon com www vertilon com Component Locations and Functions Figure 9 Top Component Locations and Functions 57 40 4 20 4 20 57 40 39 40 1 2 J2 39 40 1 2 J1 TJ1 SW1 1 ON 2 3 4 J7 J3...
Page 17: ...070 info vertilon com www vertilon com Figure 10 Bottom Component Locations and Functions A1 B1 C1 D1 E1 F1 G1 H1 A2 B2 C2 D2 E2 F2 G2 H2 A3 B3 C3 D3 E3 F3 G3 H3 A4 B4 C4 D4 E4 F4 G4 H4 A5 B5 C5 D5 E5...
Page 18: ...Test input for factory use only Table 3 Connectors Name Function Description LD1 STATUS Bicolor red green LED indicator for SIB864 status SW1 1 2 DEV ADDR 1 0 Sets the device address for control by t...
Page 19: ..._CLK1 4 P16 5 P32 6 P48 5 P64 6 P15 7 P31 8 P47 7 P63 8 P14 9 P30 10 P46 9 P62 10 P13 11 P29 12 P45 11 P61 12 P12 13 P28 14 P44 13 P60 14 P11 15 P27 16 P43 15 P59 16 P10 17 P26 18 P42 17 P58 18 P9 19...
Page 20: ...MA 01886 Tel 978 692 7070 info vertilon com www vertilon com Mechanical Information Figure 11 SIB864 Printed Circuit Board Dimensions ALL DIMENSIONS IN MILLIMETER PEM mounting nut 4 40 bottom side mou...
Page 21: ...ut limitation loss of use loss or alteration of data delays lost profits or savings arising from the use of this document or the product which it accompanies Vertilon reserves the right to change this...