Physical specifications
Wave IP 500
Wave IP 2500
Environmental requirements
For the Wave Server to operate properly, the environmental specifications in the following table
must be met
All models.
Dimensions
2.6 inches high x 17.6 wide x 13.8 inches deep (6.4 x 44.7 x 34.9 cm), 1.5U
rack height)
Weight
14 pounds (6.4 kg)
Dimensions
Base unit: 4.4 inches high x 17.6 wide x 17.9 deep (11.1 x 44.7 x 45.5 cm),
2.5U rack height
EXU: 2.6 inches high x 17.6 wide x 17.9 deep (6.4 x 44.7 x 45.5 cm),
1.5U rack height
Weight
Base unit: 26 pounds (11.8 kg)
EXU: 19 pounds (8.6 kg)
Requirement
Value or range
Operating temperature
32° to 104° F (0° to 40° C)
Operating humidity
80% maximum relative humidity, noncondensing
Operating altitude
Up to 10,000 ft (3050 m)
Storage temperature
-4° to 140° F (-20° to 60° C)
Storage humidity
85% maximum relative humidity, noncondensing
Clearance for servicing
Minimum 24 in (61 cm) front and back
Clearance for cooling
Minimum 4 in (10 cm) on all sides
AC power requirements,
E1 internal power supply
Base unit: 100-240 VAC, 50/60 Hz, 9A
EXU: 6A