6-10
I
NSTALLING
I
NTEL
T
ELEPHONY
C
OMPONENTS
Connecting E1 CAS trunk boards
Connect the E1 CAS trunk lines from the telephone company directly into the Intel Dialogic E1
trunk board.
Connecting ISDN BRI trunk boards
See “Additional required hardware for ISDN BRI service in Chapter 4 in Installing TeleVantage.
The connection procedure for an ISDN BRI trunk board depends on which board you are using.
To connect BRI/x-PCI boards
1.
Connect the ISDN BRI trunk lines from the telephone company to the Network
terminal type 1 adapter (NT1).
2.
Connect the NT1 to the Intel Dialogic shielded breakout box using the custom shielded
RJ-45 cable specified in “Additional required hardware for ISDN BRI service in
Chapter 4 in Installing TeleVantage.
3.
Connect the Intel Dialogic shielded breakout box to the Intel Dialogic BRI board using
a Intel Dialogic SCSI-3 BRI breakout box cable.
To connect BRI/2VFD boards
Connect the trunk lines from the telephone company directly to the Intel Dialogic board using a
custom RJ-48 cable, specified in the documentation that comes with the board.
When you have connected all of your trunk boards, go to the next section.
Summary of Contents for TeleVantage 7.5
Page 1: ...INSTALLING INTEL TELEPHONY COMPONENTS TELEVANTAGE 7 5 ...
Page 2: ......
Page 4: ......
Page 14: ......
Page 15: ...Section 1 Preparing for Installation ...
Page 16: ......
Page 30: ......
Page 31: ...Section 2 Installing Intel HMP ...
Page 32: ......
Page 50: ......
Page 51: ...Section 3 Installing Intel Boards and Drivers ...
Page 52: ......
Page 72: ......
Page 116: ......
Page 117: ...Appendixes ...
Page 118: ......
Page 126: ......
Page 154: ......
Page 174: ......
Page 180: ......