G
ETTING
S
TARTED
> S
HORTCUTS
TO
H
ELP
Y
OU
W
ORK
F
ASTER
DX-80 Programming Manual
- 48 -
2. The system places the cursor in the
Source DIR No
. field. Key in the CO line directory number you want to
use as a baseline, and press
Enter
. Valid directory numbers are 740 through 755. There is no default. Once
you enter a valid CO group number, the system moves you to the
Destination DIR No.
field.
3. Enter the CO group number you want to copy the baseline’s programming into (9 and 800 through 806) and
press
Enter
. Once you enter a valid CO group number, the system accepts that number and scrolls down a
line to allow you to enter another CO group number into which you want to copy the baseline’s program-
ming.
Note
: If you enter an invalid number, the system erases your input.
4. In the same manner, enter any other CO group numbers as needed. When you are finished copying the set-
ups, press
Esc
. The system then performs the CO group copy that you specified, and returns you to the Sys-
tem Application — CO Line Copy Group menu.
5. If needed, you can enter another source CO line directory number to copy from, and continue the process
for other CO groups.
6. When you are done, press
Esc
to return to the Database Programming screen. The system prompts: “Exit
This Feature?”; press
Y
for yes.
7. The system prompts “Save Current Setting?” Press
Y
to save your changes.
8. The system then prompts “File Exists, Override?” Press
Y
to continue with the save operation.
9. Press
Esc
to return to the Database Programming menu.
10. When you have finished all programming changes, perform a Send operation to copy your new database to
the DX-80 switch system memory. For more details, see Section 2.1.4.4,
3.1.3 COPYING BASELINE EXTENSION SETUPS
You can use this database feature to quickly copy the various programming and settings for one extension to other
extensions. There are two methods to copy extension data:
• individual—copies from the baseline extension to another extension, one at a time;
• group—copies from the baseline extension to all extensions in a pick up group.
The following conditions apply to copying extension programming.
• You must complete all the programming for the baseline extension before making a copy. For details on how
Summary of Contents for Comdial DX-80
Page 1: ...Programming Manual Technical Manual Volume II GCA60 001 RB1105 ...
Page 4: ... iv This Page Intentionally Left Blank ...
Page 18: ...This page intentionally left blank ...
Page 58: ...GETTING STARTED SHORTCUTS TO HELP YOU WORK FASTER DX 80 Programming Manual 58 ...
Page 291: ... 291 A WORKSHEETS Worksheets DX 80 Programming Manual ...
Page 292: ...APPENDIX A DX 80 Programming Manual 292 ...
Page 293: ... 293 DX 80 Programming Manual APPENDIX A ...
Page 294: ...APPENDIX A DX 80 Programming Manual 294 ...
Page 295: ... 295 DX 80 Programming Manual APPENDIX A ...
Page 296: ...APPENDIX A DX 80 Programming Manual 296 ...
Page 297: ... 297 DX 80 Programming Manual APPENDIX A ...
Page 298: ...APPENDIX A DX 80 Programming Manual 298 ...
Page 299: ... 299 DX 80 Programming Manual APPENDIX A ...
Page 300: ...APPENDIX A DX 80 Programming Manual 300 ...
Page 301: ... 301 DX 80 Programming Manual APPENDIX A ...
Page 302: ...APPENDIX A DX 80 Programming Manual 302 ...
Page 303: ... 303 DX 80 Programming Manual APPENDIX A ...
Page 304: ...APPENDIX A DX 80 Programming Manual 304 ...
Page 308: ...APPENDIX B DX 80 Programming Manual 308 This Page Intentionally Left Blank ...
Page 321: ... 321 DX 80 Programming Manual INDEX This page intentionally left blank ...