Typical MDF Installation
The following example install illustrates a two-cabinet installation using the MDF installation method.
“Station” cables
from telephones
Dedicated AC outlet
(i.e., the dedicated
outlet must have no
other equipment
connected to it on
this circuit breaker).
#10 AMG
Ground
66M1-50 Blocks
KSU
Termination
Paging
Equipment
(or other
third-party
equipment)
66M1-50 Blocks
Ancillary
Equipment
(paging, music
sources, etc.)
66M1-50 Blocks
“Station” Phone
Cable
Terminations
DX-120
KSU 1
66M1-50
•
The 66M1-50 is split into a left and right half for
termination wiring.
•
Each row conducts between the two left
columns and the two right columns. This is the
source of the term “Split 50”
•
Be sure to treminate cable pairs from the KSU
and from telephone locations on outer column
pins (one lead only per pin).
IMPORTANT!
NEVER
terminate two wires on one pin!
This is refered to as “double-punching”
and causes poor connection of wires on
the terminal.
NOTE
When used with “Bridging Clips”, the Split
50 Block can be used to isolate trouble in
wiring.