A
CCESSING
PC-DBA M
AINTENANCE
DX-120 Installation and Maintenance Manual
- 110 -
Maintenance Utilities (continued)
T1 M
AINTENANCE
The DX-120 provides an easy and efficient way to track and report errors that may occur during its operation.
There are three tools that allow for tracking and clearing of errors:
• T1 Error Threshold
• Error Seconds Total
• Clear T1 Error
T1 ERROR THRESHOLD
You can set the number of errors (for each error type) per second that you will allow to occur before registering an
error in the total count. The default setting for each error type is -0-. (zero)
NOTE
It is recommended that you leave the threshold settings as is (i.e., keep the
default settings). However, if there is no need to track the errors, you can set the
count higher so they don't register at all.
1) Go to Maintenance
X
T1 Maintenance
X
Error Threshold to display the Error Threshold screen.
2) Enter the number of totals to be tracked before a total is registered.
3) Click Send to complete the setting:
4) Use the Error Seconds Total to review error results at any time (see below).
T1 Maintenance (continued on next page)