A
CCESSING
PC-DBA M
AINTENANCE
DX-120 Installation and Maintenance Manual
- 108 -
Maintenance Utilities (continued)
BLOCK CONTROL
You can use Block Control to restrict access to certain system resources for the purposes of trouble-shooting, e.g.
you might block a CO line from use in order to test the circuit while avoiding user access to the CO line circuit. To
use Block Control, you must know the cabinet number, board/module number and port number.
From the main PC-DBA Screen
(during connection between the system and the switch - see page 84
):
1) Go to Maintenance
X
Remote Control
X
Block Control to display the Block Control screen.
2) Select the number of the board you want to block (or unblock).
IMPORTANT
When a board or port is blocked, it must be unblocked to regain access to the
resource.
EXAMPLE
3) Choose whether you want to block or unblock the selected board.
AND/OR
Block Control
(continued on next page)
Block Control can
be used to block
access to a board
or a port. The
specific board/
module and/or port
number must be
known.
When a board or port is
blocked, it must be
Unblocked to regain access
to the resource.
Summary of Contents for comdial DX-120
Page 1: ...Installation and Maintenance Manual Technical Manual Volume I ...
Page 6: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 46: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 138: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 144: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 145: ......