Vehicle serial number
Date and time
Flight time
Link to the on-board log and/or flight review
Operator
Weather conditions / wind speed
Flight notes, failures, damage and field replacements
Preventative maintenance
To keep your DeltaQuad in proper condition the following steps should be taken:
After every flight
Clean the propellers of any dirt and inspect for damage.
Clean the fuselage and wings, this will improve performance.
Inspect the avionics, make sure all components are still securely attached in their proper place and all
connectors are securely fastened.
Inspect motor and servo linkage screws. Should they have come undone, lock bond must be used on all
screws when re-attaching.
After 200 flights or 12 months
To keep your vehicle in the best condition and safe to operate beyond this point
should be performed. This entails the preventive replacement of many components and a thorough
inspection and test flight.
Replacing components
The DeltaQuad has been designed to allow easy replacement of components. Every component on the
DeltaQuad is available as a replacement part. If you require replacements parts please contact Vertical
Technologies.
When replacing motors or elevon linkages, lock bond must be used on all screws and nuts.