Operational Adjustments
Adjustment Section
©Vertical Express
2-40
Printed in USA April 2020
Additional Operational Adjustments
Verify the following settings:
1. TIM set correctly.
2. DAT set correctly.
3. L10 - L34 for lobby request (parking options) - some jobs ship with parking enabled.
4. Multistage
jacks.
a. JRT set to desired time.
b. O29 = 6-10 seconds.
c. O44 - # motor starts to trigger a jack resync.
d. O30 - Jack resync interval in days (1-3).
e. O32 - Jack resync door.
5. Fire
service.
a. F10 - Main fire return landing.
b. F11 - Alternate fire return landing.
6. Set Hoistway Access (optional).
•
Z38 - Hoistway Access Bottom Floor Door Selection
•
Z39 - Hoistway Access Top Floor Door Selection
•
O11- Hoistway Access Bottom Zone
•
O21- Hoistway Access Top Floor
•
O22- Hoistway Access Top Zone
•
Configure the Safety Processor
•
Issue TECC Command