2004 VERTEX STANDARD CO., LTD. EC035N90B
VHF FM Transceiver
VX-4200
Series
VX-4100
Series
Service Manual
Specifications ........................................................... A-1
DSUB 15-pin Accessory Connector ...................... B-1
Exploded View & Miscellaneous Parts ............... C-1
Block Diagram ......................................................... D-1
Circuit Description .................................................. E-1
Alignment ................................................................. F-1
Installation of Option ............................................ G-1
Introduction
This manual provides the technical information necessary for servicing the
VX-4200/-4100
Series Mobile Transceiv-
er.
Servicing this equipment requires expertise in handing surface-mount chip components. Attempts by non-qualified
persons to service this equipment may result in permanent damage not covered by the warranty, and may be illegal
in some countries.
Two PCB layout diagrams are provided for each double-sided board in this transceiver. Each side of the board is
referred to by the type of the majority of components installed on that side (“Side A” or “Side B”). In most cases one
side has only chip components (surface-mount devices), and the other has either a mixture of both chip and leaded
components (trimmers, coils, electrolytic capacitors, ICs, etc.), or leaded components only.
As described in the pages to follow, the advanced microprocessor design of the
VX-4200/-4100
allows a complete
alignment of this transceiver to be performed without opening the case of the radio; all adjustments can be performed
from the personal computer, using with the Vertex Standard VPL-1 Programming Cable and CE59 Software.
While we believe the information in this manual to be correct, Vertex Standard assumes no liability for damage that
may occur as a result of typographical or other errors that may be present. Your cooperation in pointing out any
inconsistencies in the technical information would be appreciated.
Contents
Board Units (Schematics, Layouts & Parts)
RF Unit ................................................................. H-1
FRONT-C Unit (VX-4100) ................................... I-1
FRONT-D Unit (VX-4200) ................................... J-1
Optional Units (Schematics, Layouts & Parts)
FVP-25 Encryption/DTMF Pager Unit ............. K-1
DVS-5 Voice Storage Unit .................................. L-1
VTP-50 VX-Trunk Unit ..................................... M-1
VERTEX STANDARD CO., LTD.
4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan
VERTEX STANDARD
US Headquarters
10900 Walker Street, Cypress, CA 90630, U.S.A.
YAESU EUROPE B.V.
P.O. Box 75525, 1118 ZN Schiphol, The Netherlands
YAESU UK LTD.
Unit 12, Sun Valley Business Park, Winnall Close
Winchester, Hampshire, SO23 0LB, U.K.
VERTEX STANDARD HK LTD.
Unit 5, 20/F., Seaview Centre, 139-141 Hoi Bun Road,
Kwun Tong, Kowloon, Hong Kong
A
P2
P1
P3
P4
P2
P1
TX/BUSY
A
1
2
3
4
VX-4200
Series
VX-4100
Series
Summary of Contents for VX-4100 Series
Page 4: ...Note B 2 ...
Page 7: ...D 1 Block Diagram RF Unit ...
Page 8: ...D 2 Block Diagram FRONT C Unit VX 4100 FRONT D Unit VX 4200 ...
Page 14: ...Installation of Option Note G 2 ...
Page 16: ...RF Unit Lot 1 H 2 Note ...
Page 19: ...RF Unit Lot 2 H 5 Circuit Diagram ...
Page 20: ...RF Unit Lot 2 H 6 Note ...
Page 23: ...RF Unit Lot 3 5 H 9 Circuit Diagram ...
Page 24: ...RF Unit Lot 3 5 H 10 Note ...
Page 27: ...RF Unit Lot 6 H 13 Circuit Diagram ...
Page 28: ...RF Unit Lot 6 H 14 Note ...
Page 47: ...I 3 FRONT C Unit VX 4100 Lot 6 Circuit Diagram ...
Page 53: ...J 3 FRONT D Unit VX 4200 Lot 6 Circuit Diagram ...
Page 59: ...L 1 DVS 5 Voice Storage Unit Option Circuit Diagram ...