Vertex Standard VX-2200E Series Operating Manual Download Page 1

VX-2200E

 

S

ERIES

O

PERATING

 M

ANUAL

VERTEX STANDARD CO., LTD.

4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan

VERTEX STANDARD

US Headquarters

10900 Walker Street, Cypress, CA 90630, U.S.A.

YAESU EUROPE B.V.

P.O. Box 75525, 1118 ZN Schiphol, The Netherlands

YAESU UK LTD.

Unit 12, Sun Valley Business Park, Winnall Close

Winchester, Hampshire, SO23 0LB, U.K.

VERTEX STANDARD HK LTD.

Unit 5, 20/F., Seaview Centre, 139-141 Hoi Bun Road,

Kwun Tong, Kowloon, Hong Kong

VERTEX STANDARD 

(

AUSTRALIA

)

 PTY., LTD.

Normanby Business Park, Unit 14/45 Normanby Road

Notting Hill 3168, Victoria, Australia

Summary of Contents for VX-2200E Series

Page 1: ... A YAESU EUROPE B V P O Box 75525 1118 ZN Schiphol The Netherlands YAESU UK LTD Unit 12 Sun Valley Business Park Winnall Close Winchester Hampshire SO23 0LB U K VERTEX STANDARD HK LTD Unit 5 20 F Seaview Centre 139 141 Hoi Bun Road Kwun Tong Kowloon Hong Kong VERTEX STANDARD AUSTRALIA PTY LTD Normanby Business Park Unit 14 45 Normanby Road Notting Hill 3168 Victoria Australia ...

Page 2: ... in vehicle mount configurations with a maximum oper ating duty factor not exceeding 50 in typical Push to Talk configurations This radio is restricted to occupational use work related operations only where the radio operator must have the knowledge to control the exposure conditions of its passengers and bystanders by maintaining the minimum separation distance shown below Antenna Installation Fo...

Page 3: ...features provided on the VX 2200E Series transceiver After reading this manual you may wish to consult with your Network Administrator regarding precise details of the configuration of this equipment for use in your application NOTICE There are no owner serviceable parts inside the transceiver All service jobs must be referred to an authorized VERTEX STANDARD Service Represen tative Consult your A...

Page 4: ...ick stop to turn the radio off d Microphone Jack Connect the microphone plug to this jack e P1 P4 Buttons Programmable Function Buttons These buttons can be set up for special applications such as High Low power selection Monitor Talk Around etc as determined by your network require ments and programmed by your VERTEX STANDARD dealer f T S Buttons Programmable Function Buttons In the factory defau...

Page 5: ...transceiver s Transmit Receive Status Steady Red Transmitting in progress Steady Green Signaling Off Blinking Green Busy Channel Squelch Off CONTROLS CONNECTORS Call indicator Dual Watch is activated Low Transmt Power Mode ON Scan is activated Priority Scan is activated Talk Around is enabled Receiver Monitor Group Scan is enabled AUX A Port is activated 8 Character Alpha numeric Display Encryptio...

Page 6: ...9 plug e D Sub 15 Pin Accessory Connector External TX audio line input PTT Push To Talk Squelch and external RX audio line output signals may be obtained from this connector for use with acces sories such as data transmission reception modems and external Channel con trol input etc f External Speaker Jack An external loudspeaker may be connected to this 2 contact 3 5 mm mini phone jack Caution Do ...

Page 7: ...sure it is clear Press the PF button which is programmed to the Monitor feature to listen for channel activity When receiving a call transmit only after the incoming call ends The radio cannot receive a call and transmit simultaneously Press the PTT switch If the channel is clear the TX BUSY indicator will glow red The radio is now transmitting While holding in the PTT switch speak across the face...

Page 8: ... the VX 2200E s keys may be locked out To activate the Locking feature press and hold in the P1 key while turning the radio on To disable the Locking feature repeat this power on procedure ADVANCED OPERATION Programmable Function PF Buttons The VX 2200E Series includes six Programmable Function PF Buttons The PF button functions can be customized via programming by your VERTEX STAN DARD dealer to ...

Page 9: ... Down Group Up Group Down SCAN SCAN SET Group SCAN Group SCAN SET DW Dual Watch Follow Me SCAN Follow Me DW LOW TA Talk Around TA SCAN EncryptionÚ Emergency RESET CALL 1 CALL 2 CALL 3 DTMF CODE SET Code Up Code Down Code SET Speed Dial Public Address EXT ACC1 EXT ACC2 Direct CH 1 Direct CH 2 AF Min Vr Lone Worker HA Horn Alert Key Lock SET P1 P2 P3 P4 S S S S S T T T T T ADVANCED OPERATION ...

Page 10: ...appears on the display Press the T S button to select the desired squelch level Press this key again A tone will sound and the display will revert to the normal channel indication DIMMER Press or press and hold the assigned programmable key to select the brightness level of the display Available selections are four levels CHANNEL UP DOWN Press or press and hold the assigned programmable key genera...

Page 11: ... the follow ing channels Current channel Talk Back Last Busy channel Priority channel Scan Start channel SCAN SET Press or press and hold the assigned programmable key to delete the Current Memory channel from the Scanning When you delete a Group or channel SKI SKI SKI SKI SKIP P P P P will appear on the LCD for one second after pressing the assigned programmable key To restore a particular channe...

Page 12: ...rammable key Operation will revert to the Dual Watch Start channel FOLLOW ME SCAN Follow Me Scan feature checks a User assigned Priority Channel regularly as you scan the other channels Thus if only Channels 1 3 and 5 of the 8 available chan nels are designated for Scanning the user may nonetheless assign Channel 2 as the User assigned Priority Channel via the Follow Me feature To activate Follow ...

Page 13: ...ill be retained in memory until you change it LOW POWER LOW Press or press and hold the assigned programmable key to set the radio s transmit ter to the Low Power mode Press or press and hold the key again to return to High Power operation when in difficult terrain When the radio s transmitter is set to Low Power mode the icon will be indicated on the display TALK AROUND TA Press or press and hold...

Page 14: ... you have someone monitoring on the same frequency as your transceiver s channel Press or press and hold the assigned programmable key to initiate an emergency call For further details contact your VERTEX STANDARD dealer RESET Press or press and hold the assigned programmable key to reset the RFC Ready for Communication condition or to reset the keypad entry condition CALL 1 TO CALL 3 Press or pre...

Page 15: ...y if the normal without keypad microphone is using The DTMF tones sent during the dial ing sequence will be heard in the speaker PUBLIC ADDRESS Press or press and hold the assigned programmable key to use the transceiver as a PA amplifier When you enable this function a tone sounds and PUBLIC A PUBLIC A PUBLIC A PUBLIC A PUBLIC A will appear on the display The public address can be used even while...

Page 16: ... or press and hold the programmable key which is assigned the Emergency feature or turn off the radio HA HORN ALERT Press or press and hold the assigned programmable key to turn the Horn Alert function ON or OFF If you receive a call from the base station with 2 Tone 5 Tone or DTMF signaling horn alert will be activated and your vehicles horn will sound When you turn the Horn Alert ON a tone will ...

Page 17: ...beep will sound and OUT SVC OUT SVC OUT SVC OUT SVC OUT SVC Out of Service will be displayed on the LCD for 2 seconds If you subsequently move back into communication range as soon as the other station transmits a short beep will sound and In will be displayed again on the LCD for 2 seconds DTMF Paging System Requires the optional FVP 25 Encryption DTMF Pager Unit This system allows paging and sel...

Page 18: ...B ENB ENB ENB Enables the disabling the Encryption Unit DIS DIS DIS DIS DIS Disables the disabling the Encryption Unit AF MINVR AF MINVR AF MINVR AF MINVR AF MINVR Sets the minimum Audio Volume level BEEP VR BEEP VR BEEP VR BEEP VR BEEP VR Sets the Beep Volume level CONTRAST CONTRAST CONTRAST CONTRAST CONTRAST Sets the LCD Contrast level DIMMER DIMMER DIMMER DIMMER DIMMER Sets the brightness of th...

Page 19: ...rsion Type Encryption Unit FVP 35 High Level Encryption Unit VME 100 ANI Encode Unit MDC 1200 GE STAR ANI ENCODE VT60FS VX trunk Unit w Encryption VT60F VX trunk Unit LF 1 Line Filter VPL 1 Programming Kit Computer to PC CE82 PC Programming Software FIF 10A USB Programming Interface Required the Microsoft Windows 2000 or Windows XP CT 104A Connection Cable for FIF 10A Availability of accessories m...

Page 20: ...VX 2200E SERIES OPERATING MANUAL 18 NOTE ...

Page 21: ...VX 2200E SERIES OPERATING MANUAL 19 NOTE ...

Page 22: ...VX 2200E SERIES OPERATING MANUAL 20 NOTE ...

Page 23: ...d Address of Manufacturer 4 8 8 Nakameguro Meguro Ku Tokyo 153 8644 Japan Applicable Standards This equipment is tested and conforms to the essential requirements of directive as included in following standards EN 300 086 2 Radio Standard EN 300 113 2 EN 301 489 1 EMC Standard EN 301 489 5 EN 60065 Safety Standard The technical documentation as required by the Conformity Assessment procedures is k...

Page 24: ...Copyright 2006 VERTEX STANDARD CO LTD All rights reserved No portion of this manual may be reproduced without the permission of VERTEX STANDARD CO LTD E C 0 6 1 N 1 0 0 ...

Reviews: