Base Address Configuration
VCM-DAS-3 Reference Manual
14
V3
A/D Channel 8-16 Span Range Selector
[7-8]
[5-6]
[3-4]
[1-2]
0V to +5V
In
In
In
In
0V to +10V
In
In
In
Out
-
5V to +5V
In
In
Out
In
-
10V to +10V
In
In
Out
Out
-
2.5V to +2.5V
In
Out
In
In
-
2.5V to +7.5V
In
Out
In
Out
These jumpers set the initial power up span ranges for A/D channels 8-16.
In, In, In, In
(0V to +5V)
Base Address Configuration
As shipped, the VCM-DAS-3 is configured for a base address of 0x300. The card occupies up to
16 consecutive I/O addresses in enhanced mode (only eight I/O addresses in compatible mode).
Jumper block V1[11-12] through V1[1-2] is used set the base address.
The base address can be configured from 0x000 to 0x3F0 on any 10h address boundary. Figure 7
shows how to set the address selector jumpers for the appropriate upper and middle hex digits of