Vermont Castings • Merrimack Large Insert Owner’s Manual_R15 • 11/18
3-90-30004671
Fireplace Minimums
A
Width at Face
´PP
B
:LGWKDW'LPHQVLRQµ&¶
´PP
C
Depth
1
´PP
D
+HLJKWDW)DFH
´PP
E
+HLJKWDW'LPHQVLRQµ&¶
´PP
Fireplace Maximums
H
Lintel Depth
´PP
I
Width
2
´PP
J
+HLJKW
2
´PP
7KHPLQLPXPGHSWKPXVWEHPDLQWDLQHGIURPWKHÀRRURIWKH¿UHSODFH
WRDKHLJKWRI´PP
7KRXJKWKH0HUULPDFN/DUJH,QVHUWZLOO¿WLQWRODUJHU¿UHSODFHVWKH
decorative optional Vermont Castings Group Surround Panels will
QRWFRPSOHWHO\FRYHUWKH¿UHSODFHRSHQLQJLIWKHVHGLPHQVLRQVDUH
H[FHHGHG&XVWRPPDGHWULPSLHFHVPD\EHXVHG
A,I
B
C
D,J
E
D,J
H
C
E
Figure 3
8VHWKHVHPHDVXUHPHQWVWRFRQ¿UPWKDWWKH0HUULPDFN
/DUJH,QVHUWZLOO¿WLQWR\RXUPDVRQU\¿UHSODFH
Minimum Fireplace Dimensions
7KH0HUULPDFN/DUJH,QVHUWZLOO¿WPDQ\¿UHSODFHV7RFRQ¿UP
WKDWLWZLOO¿W\RXUVPHDVXUHWKHOLQWHOGHSWKSOXVWKHKHLJKW
ZLGWKDQGGHSWKRI\RXU¿UHSODFHDQGKHDUWK&RPSDUHWKHP
WRWKHPHDVXUHPHQWVLQWKHDFFRPSDQ\LQJFKDUW,I\RXFKRRVH
WRLQVWDOODQHZKHDUWKRYHUDQH[LVWLQJ¿UHSODFHKHDUWKEH
sure to take its thickness into consideration when measuring
ERWKIURQWDQGEDFNKHLJKWRIWKH¿UHSODFHDQGFOHDUDQFHVWR
any existing trims and mantels.
NOTE:
7KHFOHDUDQFHEHWZHHQWKH0HUULPDFN/DUJH,QVHUW
DQGWKHPDQWHOWRSWULPDQGVLGHWULPFDQQRWEHUHGXFHGE\
installing shields.
$QRWKHUUHTXLUHPHQWWRFRQVLGHULVWKHFOHDUDQFHIRUPRYDEOH
LWHPV VXFK DV WDEOHV ERRNFDVHV UXJV IXUQLVKLQJV DQG
\RXUZRRGER[$OOFRPEXVWLEOHPDWHULDOVRIWKLVW\SHVKRXOG
EHDPLQLPXPRIPPIURPWKHIURQWVXUIDFHRI
WKH0HUULPDFN/DUJH,QVHUW%HVXUHWKDWIDPLO\PHPEHUV
are aware of this requirement as well, so they too will keep
REMHFWVDVDIHGLVWDQFHIURPWKHVWRYH
%HDZDUHWKDWDFKLPQH\RULJLQDOO\GHVLJQHGIRU¿UHSODFHXVH
PD\SHUIRUPGLIIHUHQWO\ZKHQXVHGWRYHQWDQDLUFRQWUROOHG
DSSOLDQFH VXFK DV \RXU 0HUULPDFN /DUJH ,QVHUW HYHQ LI
WKHÀXHLVOHVVWKDQWLPHVODUJHUWKDQWKHÀXHFROODU)RU
example, a chimney on an outside wall may not heat up
HQRXJKWRVXVWDLQDQDGHTXDWHGUDIW6XFKDÀXHFDQRIWHQ
EHLPSURYHGLILWLVUHOLQHGWRUHGXFHLWVVL]HDQGRULQVXODWHG
to keep it warmer.
$ SRVLWLYH ÀXH FRQQHFWLRQ PXVW EH PDGH EHWZHHQ WKH
,QVHUW DQG WKH ¿UVW PDVRQU\ WLOH RU SUHIDEULFDWHG PHWDO
FKLPQH\ VHFWLRQ$ SRVLWLYH ÀXH FRQQHFWLRQ FRQVLVWV RI
DSODWHWKDWVHDOVRUUHSODFHVWKH¿UHSODFHGDPSHUDQG
a section of chimney connector that passes through the
plate into the chimney.
7KHFKLPQH\FRQQHFWRUPXVWEHDPLQLPXPHTXLYDOHQWWR
DPPGLDPHWHURSHQLQJDQGPXVWEHJDXJH
or heavier stainless steel.
&KLPQH\&RQQHFWLRQV\VWHPVDUHDYDLODEOHIURPDYDULHW\
of manufacturers. Your Vermont Castings dealer can
UHFRPPHQGDV\VWHPWKDWZLOOEHVWPHHWWKHUHTXLUHPHQWV
of your particular installation.
Sealing Requirements / U.S.
7KHFKLPQH\PXVWEHVHDOHGRIIIURPURRPDLUHLWKHUE\
DSODWHDWWKHGDPSHUOHYHORUE\VHDOLQJWKH¿UHSODFH
opening.
8QXVHG RSHQLQJV WR WKH ÀXH PXVW EH VHDOHG ZLWK
PDVRQU\WRWKHWKLFNQHVVRIWKHFKLPQH\ZDOO2SHQLQJV
VHDOHGZLWKSLHSODWHVRUZDOOSDSHUDUHDKD]DUG,Q
WKHHYHQWRIDFKLPQH\¿UHÀDPHVDQGVPRNHPD\
EHIRUFHGIURPWKHRSHQLQJV
In Canada (CAN/CSA-B365-M91, Section 5):
7KLV¿UHSODFHLQVHUWPXVWEHLQVWDOOHGZLWKDFRQWLQXRXV
FKLPQH\OLQHURIPPGLDPHWHUH[WHQGLQJIURPWKH
¿UHSODFHLQVHUWWRWKHWRSRIWKHFKLPQH\7KHFKLPQH\
liner must conform to the Class 3 requirements of CAN/
8/&6
6WDQGDUG IRU /LQLQJ 6\VWHPV IRU ([LVWLQJ
0DVRQU\RU)DFWRU\%XLOW&KLPQH\VDQG9HQWV
, or CAN/
8/&6
6WDQGDUGIRU/LQLQJ6\VWHPVIRU1HZ0DVRQU\
&KLPQH\V
.
7KHRSHQLQJRIWKH¿UHSODFHDURXQGWKHLQVHUWPXVWEH
VHDOHGWRSUHYHQWURRPDLUSDVVLQJWRWKH¿UHSODFHFDYLW\
([LVWLQJDLUFLUFXODWLRQFKDPEHUVLQD¿UHSODFHZLWKDVWHHO
OLQHUPD\QRWEHEORFNHG
3URYLVLRQPXVWEHPDGHIRUUHPRYDORIWKHLQVHUWWRFOHDQ
WKHFKLPQH\ÀXH
7KHH[LVWLQJ¿UHSODFHGDPSHULIDQ\VKRXOGEHORFNHG
in the open position.
$SHUPDQHQWPHWDOZDUQLQJODEHOPXVWEHDI¿[HGWRWKH
EDFNRIWKH¿UHSODFHVWDWLQJWKH¿UHSODFHPD\KDYHEHHQ
DOWHUHGWRDFFRPPRGDWHWKHLQVHUWDQGPD\EHXQVDIHWR
XVHDVDFRQYHQWLRQDO¿UHSODFH$)LUHSODFH0RGL¿FDWLRQ
7DJLVLQFOXGHGLQWKHKDUGZDUHEDJLQVLGHWKH0HUULPDFN
/DUJH,QVHUW