background image

30

Encore Woodburning Stove

30003842

   

Shell Enamel Parts - Encore

 

Enamel 

 

 

 

 

 

 

 

  Color 

Top 

Left Side 

Right Side 

Front 

Ashlip 

Single Leg

 

Classic 

1308618 

1308623 

1308619 

1308635 

1307406 

1307427

  Biscuit 

30003007 

30003006 

30003005 

30003004 

30003002 

30003003

  Bordeaux 

2328618 

2328623 

2328619 

2328635 

2377406 

2327427

  Chestnut Brown 

30003019 

30003018 

30003017 

30003016 

30003014 

30003015

  Ebony 

30003031 

30003030 

30003029 

30003028 

30003026 

30003027

  Forest Green 

2318618 

2318623 

2318619 

2318635 

2317406 

2317427

  Midnight Blue 

2378618 

2378623 

2378619 

2378635 

2377406 

2377427

  Sand 

1328618 

1328623 

1328619 

1328635 

1327406 

1327427

  Suede Brown 

30002526 

30002524 

30002523 

30002522 

30002520 

30002521

  Vermont 

 

 

 

 

 

 

 

  Classic Green 

30003044 

30003043 

30003042 

30003041 

30003039 

30003040

   

Shell Enamel Parts - Encore

 

Enamel 

 

Left Door 

Left Door 

Right Door 

Right Door 

  Color 

Flue Collar 

Subassembly 

Only 

Subassembly 

Only

  Classic 

1304280 

5008648 

1308637 

5008647 

1308636

  Biscuit 

30003008 

30003012 

30003010 

30003011 

30003009

  Bordeaux 

2324280 

30001144 

2328637 

30001143 

2328636

  Chestnut Brown 

30003020 

30003024 

30003022 

30003023 

30003021

  Ebony 

30003032 

30003037 

30003034 

30003036 

30003033

  Forest Green 

2314280 

30001150 

2318637 

30001149 

2318636

  Midnight Blue 

2374280 

30001345 

2378637 

30001344 

2378636

  Sand 

1324280 

30001146 

1328637 

30001145 

1328636

  Suede Brown 

30002527 

30002531 

30002529 

30002530 

30002528

  Vermont 

 

 

 

 

 

  Classic Green 

30003045 

30003049 

30003047 

30003048 

30003046

Encore Woodburning Stove

Model 2550CE (continued)

Summary of Contents for Encore 2550CE

Page 1: ...PERLY INSTALLED OPERATED AND MAIN TAINED A HOUSE FIRE MAY RESULT TO REDUCE THE RISK OF FIRE FOLLOW THE INSTALLATION INSTRUCTIONS FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE BODILY INJ...

Page 2: ...s useful information on maintenance and assembly of this product We urge you to read the manual thoroughly and to keep it as a reference Sincerely All of us at CFM Corporation Welcome This manual desc...

Page 3: ...nector for 8 ue collar 203 mm 8 diameter for 6 ue collar 152 mm 6 diameter Chimney ue size for 8 ue collar 203 mm 8 minimum for 6 ue collar 152 mm 6 minimum Flue exit position Reversible top or rear P...

Page 4: ...SE FIRE FOLLOW ALL INSTRUCTIONS EXACTLY AND DO NOT ALLOW MAKESHIFT COM PROMISES TO ENDANGER PROPERTY AND PER SONAL SAFETY All local regulations including those referring to national and European stand...

Page 5: ...y chimney with a nominal ue size of 203 x 203 mm 8 x 8 or 203 x 305 mm 8 x 12 and into a round ue with nominal ue size of 203 mm 8 An Encore with a 152 mm 6 ue collar is approved for venting into a ma...

Page 6: ...uipped with the 203 mm 8 ue collar an oval to round adapter will be needed Double wall oval to round adapters are available from some manufacturers Your local dealer can help you select the right conn...

Page 7: ...ramic or metal must be cemented securely in place The thimble sleeve should protrude 1 2 25 50mm into the room Fig 6 Use furnace cement and thin gasket ing to seal the sleeve in place in the thimble S...

Page 8: ...ombustible wall If you are considering a wall pass through in your installation check with your building inspector before you begin Also check with the chimney connector manufacturer for any speci c r...

Page 9: ...d its connector and nearby combustibles Clearance is the distance between either your stove measured from the bottom edge of the stove s top plate or chimney connector and nearby walls oors the ceilin...

Page 10: ...masonry other than to allow safe access to the controls of the stove For this reason minimum side clearances of 125 mm and a minimum rear clearance of 50 mm are recommended Summary of Clearances Minim...

Page 11: ...eld a t l e a s t 3 x D at least 1 5 x D at least 1 5 x D Plan Without Shield Plan With Shield Air space of at least 12 mm between noncombustible shield and combustible material Fluepipe at least 1 5...

Page 12: ...verse the ue collar by removing the two 2 screws that attach it to the back of the stove Be sure the gas ket around the ue collar opening is in position when you screw the collar back onto the stove I...

Page 13: ...otter and faster while less air prolongs the burn at a lower heat level High and low settings appear in Figure 20 For the greatest air supply and maximum heat output but the shortest burn time move th...

Page 14: ...rared Re ective Glass Panels for Clear Fire Viewing The inner surfaces of the infrared re ective glass panels are kept at a higher temperature than the outer surface This design along with a preheated...

Page 15: ...nstallation s draft or the force that moves air from the stove up through the chimney Draft is affected by such things as the length type and location of the chimney local geography nearby obstruction...

Page 16: ...dium to high ring rate must be maintained until the stove catalyst and fuel are all stabilized at the proper operating temperatures Even though it is possible for the re to get quite hot within a few...

Page 17: ...t The draft management information on Page 25 will explain in detail how the features of your installation may help or hinder good draft Refuel While the Embers Are Still Hot When reloading best resul...

Page 18: ...ial in soil or otherwise locally dispersed it should be kept in the closed container until all cinders have thoroughly cooled You can use wood ash as a garden fertilizer CAUTION Never use your househo...

Page 19: ...y won t lose its heat to the outdoors so it takes less heat from the stove to heat it up and keep it warm Flue Sizing The inside size of a chimney for an airtight stove should match the size of the st...

Page 20: ...aft pulls them out of the rebox The gases back up in the rebox till they re dense enough and hot enough to ignite If your stove back puffs you should open the damper to let the smoke rise to the ue mo...

Page 21: ...the glass in the doors is damaged If you need to replace the glass use only the high tem perature ceramic glass supplied by Vermont Castings Do not use substitutes Be sure to specify left or right gla...

Page 22: ...mostat handle position does not lead to changes in the re s intensity it is probably due to weak chimney draft in the case of a weak re you can t increase or an air leak in the stove in the case of a...

Page 23: ...ual or if the cata lytic element is deactivated or removed Under normal operating conditions the catalytic com bustor should remain active for two to six years de pending on the amount of wood burned...

Page 24: ...s 5 16 The damper to the upper reback the front doors to the stove front and the doors to each other 6 Check the combustor s honeycomb like element for a buildup of y ash If any is evident take the co...

Page 25: ...ogether If this is the case the job should be done only by a quali ed service technician 5 16 diameter gasket seals the following parts The ue collar to the stove back The lower reback to the sides Th...

Page 26: ...ot inspect or clean the chimney yourself contact your local Vermont Castings Dealer or a profes sional chimney sweep Annual Maintenance Every Spring at the end of the heating season perform a thorough...

Page 27: ...des more places for creosote and y ash to deposit It is important to follow the operating instructions in order to minimize these deposits and to periodically inspect your catalyst for signs of blocka...

Page 28: ...84 74 83 43 8 24 24 88 87 86 80 82 80 22 22 85 0956 Encore parts 8 02 89 92 91 90 93 93 56 Encore Woodburning Stove Model 2550CE Item Description Part Number Item Description Part Number 1 Secondary A...

Page 29: ...y Air Rod Only 1601493 43 Primary Air Regulatory System 5000337 44 Bottom 1308604 45 Ashlip See Chart Pg 36 50 Andiron 2 1307419 51 Leg See Chart Pg 36 52 Leg Leveler 1201745 53 Ashdrop 1308603 54 Paw...

Page 30: ...4 30002523 30002522 30002520 30002521 Vermont Classic Green 30003044 30003043 30003042 30003041 30003039 30003040 Shell Enamel Parts Encore Enamel Left Door Left Door Right Door Right Door Color Flue...

Page 31: ...e 3 Date of failure of catalyst 4 Any relevant information or circumstances regarding determina tion of failure 5 In addition the owner must return the failed catalyst Exclusions Limitations 1 This wa...

Page 32: ...2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation...

Reviews: