background image

14

Encore Woodburning Stove

30003842

The damper is 

closed

 when the handle points 

forward

Smoke from the fire is directed through the catalytic 
combustion system where it can be further burned for 
greater efficiency, before passing up the chimney. 

When closing the damper, be sure to pull firmly 
enough to snap it into the locked position.

ST638

Encore

damper control 

2/01

Damper Positions

Open

(Updraft Mode)

Closed

(Catalytic Mode)

ST638

Fig. 21

  The damper is either open or closed. There are no 

intermediate positions.

Two Ways to Add Fuel

The Encore’s griddle lifts for convenient top-loading of 
logs, and is the easiest way to regularly add fuel.
In addition, however, the front doors open for adding an 
occasional log to a fire.  

The Encore is not approved 

in Europe for operation with the front doors open.

To open the front doors, insert the handle into the door 
latch stub and turn it to the left and up. (Fig. 23) 

ST639

Encore

griddle open

3/1/01   djt

Handle

Quadrants

ST639

Fig. 22

  the Encore’s hinged griddle makes it easy to top-load 

wood.

To reduce the risk of breaking the glass, avoid striking 
the glass or slamming the doors.
When not using the door handle, store it in the holder 
behind the right front leg of the stove. 

ST544

door open

11/00

Clockwise to 

OPEN

Counterclockwise 

to CLOSE

ST544

Fig. 23

  To open the front doors, turn the handle clockwise.

This stove is designed to operate efficiently with 
the fire doors (front doors and griddle) closed. The 
firebox and ash doors should be kept closed at all 
times except when refuelling or removing ashes.

Infrared Reflective Glass Panels 

for Clear Fire Viewing

The inner surfaces of the

 infrared reflective glass

 

panels are kept at a higher temperature than the outer 
surface. This design, along with a preheated ‘airwash,’ 
makes clear fire viewing possible at most levels of 
operation.

Andirons Help Protect the Glass

Your stove has andirons to keep logs away from the 
glass panels. The andirons are essential to maintain 
clear fireviewing, and should be left permanently in 
place. Since the andirons may slightly hinder refueling 
through the front doors, most stove owners will prefer 
the convenience of top loading through the griddle.

Burn Only High-Quality Wood

The Encore is designed to burn natural wood only;  do 
not burn fuels other than that for which it was designed.  
You’ll enjoy the best results when burning wood that 
has been adequately air-dried. Avoid burning “green” 
wood that has not been properly seasoned, or cord-
wood dried more than two years. 

Do not burn con-

struction materials

; they often contain chemicals and 

metals that can damage the catalytic combustor.  The 
wood should be 400-500 mm (18-20”) in length. 
The best hardwood fuels include oak, maple, beech, 
ash, and hickory that has been split, stacked, and air-
dried outside under cover for at least one year.  
If hardwood is not available, you can burn softwoods 
which include tamarack, yellow pine, white pine, East-
ern red cedar, fir, and redwood. These too should be 
properly dried.  

To close them, always close the left door first.  Turn the 
handle in the right door to the left and up (to the open 
position) and close it. Finally, push on the door as you 
turn the handle to the right and down. The doors will 
draw in slightly, and the handle should offer some resis-
tance as you turn it to the closed position. 

Summary of Contents for Encore 2550CE

Page 1: ...PERLY INSTALLED OPERATED AND MAIN TAINED A HOUSE FIRE MAY RESULT TO REDUCE THE RISK OF FIRE FOLLOW THE INSTALLATION INSTRUCTIONS FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE BODILY INJ...

Page 2: ...s useful information on maintenance and assembly of this product We urge you to read the manual thoroughly and to keep it as a reference Sincerely All of us at CFM Corporation Welcome This manual desc...

Page 3: ...nector for 8 ue collar 203 mm 8 diameter for 6 ue collar 152 mm 6 diameter Chimney ue size for 8 ue collar 203 mm 8 minimum for 6 ue collar 152 mm 6 minimum Flue exit position Reversible top or rear P...

Page 4: ...SE FIRE FOLLOW ALL INSTRUCTIONS EXACTLY AND DO NOT ALLOW MAKESHIFT COM PROMISES TO ENDANGER PROPERTY AND PER SONAL SAFETY All local regulations including those referring to national and European stand...

Page 5: ...y chimney with a nominal ue size of 203 x 203 mm 8 x 8 or 203 x 305 mm 8 x 12 and into a round ue with nominal ue size of 203 mm 8 An Encore with a 152 mm 6 ue collar is approved for venting into a ma...

Page 6: ...uipped with the 203 mm 8 ue collar an oval to round adapter will be needed Double wall oval to round adapters are available from some manufacturers Your local dealer can help you select the right conn...

Page 7: ...ramic or metal must be cemented securely in place The thimble sleeve should protrude 1 2 25 50mm into the room Fig 6 Use furnace cement and thin gasket ing to seal the sleeve in place in the thimble S...

Page 8: ...ombustible wall If you are considering a wall pass through in your installation check with your building inspector before you begin Also check with the chimney connector manufacturer for any speci c r...

Page 9: ...d its connector and nearby combustibles Clearance is the distance between either your stove measured from the bottom edge of the stove s top plate or chimney connector and nearby walls oors the ceilin...

Page 10: ...masonry other than to allow safe access to the controls of the stove For this reason minimum side clearances of 125 mm and a minimum rear clearance of 50 mm are recommended Summary of Clearances Minim...

Page 11: ...eld a t l e a s t 3 x D at least 1 5 x D at least 1 5 x D Plan Without Shield Plan With Shield Air space of at least 12 mm between noncombustible shield and combustible material Fluepipe at least 1 5...

Page 12: ...verse the ue collar by removing the two 2 screws that attach it to the back of the stove Be sure the gas ket around the ue collar opening is in position when you screw the collar back onto the stove I...

Page 13: ...otter and faster while less air prolongs the burn at a lower heat level High and low settings appear in Figure 20 For the greatest air supply and maximum heat output but the shortest burn time move th...

Page 14: ...rared Re ective Glass Panels for Clear Fire Viewing The inner surfaces of the infrared re ective glass panels are kept at a higher temperature than the outer surface This design along with a preheated...

Page 15: ...nstallation s draft or the force that moves air from the stove up through the chimney Draft is affected by such things as the length type and location of the chimney local geography nearby obstruction...

Page 16: ...dium to high ring rate must be maintained until the stove catalyst and fuel are all stabilized at the proper operating temperatures Even though it is possible for the re to get quite hot within a few...

Page 17: ...t The draft management information on Page 25 will explain in detail how the features of your installation may help or hinder good draft Refuel While the Embers Are Still Hot When reloading best resul...

Page 18: ...ial in soil or otherwise locally dispersed it should be kept in the closed container until all cinders have thoroughly cooled You can use wood ash as a garden fertilizer CAUTION Never use your househo...

Page 19: ...y won t lose its heat to the outdoors so it takes less heat from the stove to heat it up and keep it warm Flue Sizing The inside size of a chimney for an airtight stove should match the size of the st...

Page 20: ...aft pulls them out of the rebox The gases back up in the rebox till they re dense enough and hot enough to ignite If your stove back puffs you should open the damper to let the smoke rise to the ue mo...

Page 21: ...the glass in the doors is damaged If you need to replace the glass use only the high tem perature ceramic glass supplied by Vermont Castings Do not use substitutes Be sure to specify left or right gla...

Page 22: ...mostat handle position does not lead to changes in the re s intensity it is probably due to weak chimney draft in the case of a weak re you can t increase or an air leak in the stove in the case of a...

Page 23: ...ual or if the cata lytic element is deactivated or removed Under normal operating conditions the catalytic com bustor should remain active for two to six years de pending on the amount of wood burned...

Page 24: ...s 5 16 The damper to the upper reback the front doors to the stove front and the doors to each other 6 Check the combustor s honeycomb like element for a buildup of y ash If any is evident take the co...

Page 25: ...ogether If this is the case the job should be done only by a quali ed service technician 5 16 diameter gasket seals the following parts The ue collar to the stove back The lower reback to the sides Th...

Page 26: ...ot inspect or clean the chimney yourself contact your local Vermont Castings Dealer or a profes sional chimney sweep Annual Maintenance Every Spring at the end of the heating season perform a thorough...

Page 27: ...des more places for creosote and y ash to deposit It is important to follow the operating instructions in order to minimize these deposits and to periodically inspect your catalyst for signs of blocka...

Page 28: ...84 74 83 43 8 24 24 88 87 86 80 82 80 22 22 85 0956 Encore parts 8 02 89 92 91 90 93 93 56 Encore Woodburning Stove Model 2550CE Item Description Part Number Item Description Part Number 1 Secondary A...

Page 29: ...y Air Rod Only 1601493 43 Primary Air Regulatory System 5000337 44 Bottom 1308604 45 Ashlip See Chart Pg 36 50 Andiron 2 1307419 51 Leg See Chart Pg 36 52 Leg Leveler 1201745 53 Ashdrop 1308603 54 Paw...

Page 30: ...4 30002523 30002522 30002520 30002521 Vermont Classic Green 30003044 30003043 30003042 30003041 30003039 30003040 Shell Enamel Parts Encore Enamel Left Door Left Door Right Door Right Door Color Flue...

Page 31: ...e 3 Date of failure of catalyst 4 Any relevant information or circumstances regarding determina tion of failure 5 In addition the owner must return the failed catalyst Exclusions Limitations 1 This wa...

Page 32: ...2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation...

Reviews: