background image

Encore

®

 1450CE Non-Catalytic Woodburning Stove

30003845

Congratulations on your choice of a Vermont Castings Encore. With this purchase you have made a commitment to make 
the hearth a place of warmth, beauty, and comfort in your home. At MHSC, we share that joy and appreciation for the 
hearth. You may be assured that your cast-iron Vermont Castings stove has been made with the utmost care and will pro-
vide you with many years of service.
As you become acquainted with your new stove or fireplace, you will find that its visual appearance is matched by its func-
tionality, due to cast iron’s unique capability to absorb and radiate heat. 
Also, MHSC units are among the cleanest-burning wood stoves and fireplaces available today. As an owner of a Vermont 
Castings stove, you make a strong statement for pollution-free energy. Clean burning, however, depends on both the manu-
facturer and the operator. Please read this manual carefully to understand how to properly operate and maintain your stove 
or fireplace.
At MHSC, we are equally committed to your satisfaction as a customer. That is why we maintain an exclusive network of the 
finest dealers in the industry. Our dealers are chosen for their expertise and dedication to customer service. They are fac-
tory-trained and knowledgeable about every MHSC product. Feel free to contact your Authorized Vermont Castings Dealer 
anytime you have a particular question about your stove or its performance.
This manual contains valuable instructions on the installation and operation of your Vermont Castings stove. It also contains 
useful information on maintenance and assembly of this product. We urge you to read the manual thoroughly and to keep it 
as a reference.
Sincerely,

All of  us at 

MHSC

welcome

This manual describes the installation, operation, and 
maintenance of the Vermont Castings Encore Model 
1450CE non-catalytic wood burning heater.  This heater 
meets the U.S. Environmental Protection Agency’s emis-
sion limits for wood heaters sold on or after July 1, 1990.  
Under specific test conditions this heater has been shown 
to deliver heat at rates up to 1.5 kW (4,600 BTU/hr).
The Encore Model 1450CE has been tested to current 
standards.   The test standards are UL-148 and UL-737 
for the United States, EN1340:001 + A:004 for Eu-
rope. The Encore is listed for burning wood.  Do not burn 
other fuels.  
We recommend that you hire a professional installer to in-
stall your stove, or to advise you on the installation should 
you attempt to install it yourself.
Please read this entire manual before you install and use 
your new stove.  Failure to follow instructions may result in 
property damage, bodily injury, or even death.

Specifications ................................. 3
Installation ...................................... 4
Assembly ...................................... 1
Operation ...................................... 14
Draft Management ........................ 19
Maintenance ................................. 1
Replacement Parts ....................... 5
Warranty ....................................... 8

table of contents

accessories

Warming Shelves
  #000  Classic Black  #005  Biscuit
  #001  Bordeaux 

#006  Chestnut Brown

  #00  Sand 

#007  Ebony

  #003  Midnight Blue  #008  Brown Majolica
  #004  Suede Brown  #009  Vt. Classic Green
# 017 Sparkscreen 
# 0171 Horizontal Collar Heat Shield
# 0174 Vertical Collar Heat Shield
# 365 Outside Air Kit
# 0336 Mobile Home Kit 
# 767 Variable Speed Fan Kit
# 0168 - 0169 Heat Shields for the Chimney Connec-
tor
- Matching Porcelain Stovepipe
- Matching 6” Flue Collar

Summary of Contents for Encore 1450C

Page 1: ...the risk of fire follow the installation instructions Failure to follow instructions may result in property damage bodily injury or even death Contact local building officials about restrictions and...

Page 2: ...Vermont Castings stove It also contains useful information on maintenance and assembly of this product We urge you to read the manual thoroughly and to keep it as a reference Sincerely All of us at MH...

Page 3: ...r 8 oval flue collar 203 mm 8 diameter for optional 6 flue collar 152 mm 6 diameter Chimney flue size for 8 oval flue collar 203 mm 8 minimum for optional 6 flue collar 152 mm 6 minimum Flue exit posi...

Page 4: ...low all instructions exactly and do not allow makeshift com promises to endanger property and per sonal safety All local regulations including those referring to national and European standards need t...

Page 5: ...6 and be of the twin wall insulated construction that has been approved for solid fuel use e g Rite Vent ICS of ICID Lite Chimney Systems Diameters over 200 mm 8 are not recommended due to the large...

Page 6: ...on of chimney connec tor serve as guides when you drill 3 mm 1 8 holes in the bottom of the next section Secure the chimney connector to the chimney In structions for various installations follow Be s...

Page 7: ...mble sleeve should protrude 25 51 mm 1 2 into the room Fig 6 Use furnace cement and thin gasketing to seal the sleeve in place in the thimble Secure the chimney connector to the outer end of the sleev...

Page 8: ...675 mm 26 you may install an Encore through the opening using a positive connection kit available from your lo cal dealer These positive connection kits ensure a tight fit between the stove flue colla...

Page 9: ...clearances of the hearth are as fol lows The constructed hearth should be constructed in ac cordance with the recommendations in document J and should be of minimum width 840 mm and minimum depth 840...

Page 10: ...o any combustible surfaces e g wooden mantels or lintels and to timber framed studded walls even if they are faced with noncombustible board Detailed information on fireplace and hearth construction i...

Page 11: ...ces and Fuel Storage Systems This can be achieved by following the recommenda tions of Approved Document J These are as shown in Figure 13 34 FLUEPIPE CLEARANCES D at least 3 x D Elevation Without Shi...

Page 12: ...no weight on the leg while making the adjustment Reverse the Flue Collar If Necessary Reverse the flue collar by removing the two 2 screws that attach it to the back of the stove Be sure the gas ket...

Page 13: ...ided with stove under the right wing of the bottom heat shield with two 2 10 sheet metal screws 5 Attach the rheostat to its holder by inserting the rheostat control shaft through the holder hole Inst...

Page 14: ...Andirons ST636 Fig 19 The Encore controls are conveniently located and easy to operate Door Handle A Single Air Control Regulates Heat Output and Burn Time The primary air control lever located on th...

Page 15: ...d is their density Hardwoods because of their greater density burn longer than softwoods and can increase the time between refuelings Store wood under cover to keep it dry The longer it is stored in a...

Page 16: ...far right to 1 3 the distance to left Medium From 1 3 to 2 3 the distance to left High From 2 3 the distance to left to far left DO NOT OPERATE THE STOVE WITH THE ASH DOOR OPEN OPERATION WITH THE ASH...

Page 17: ...nclude some smaller pieces of wood in the new fuel load to help the stove regain its operating temperature quickly Use this sequence as a guide to successful refueling NOTE Door handles can be hot A g...

Page 18: ...lly dispersed it should be kept in the closed container until all cinders have thoroughly cooled You can use wood ash as a garden fertilizer CAUTION Never use your household or shop vacuum cleaner to...

Page 19: ...at heat from the chimney walls will transfer to the house and not be wasted outdoors An indoor chimney will not lose its heat to the outdoors so Draft Management it takes less heat from the stove to h...

Page 20: ...voiding overly dry wood loaded into a very hot stove may help this problem If back puffing persists contact your dealer or qualified chimney sweep to help diag nose the problem Draft Testing An easy w...

Page 21: ...not use abrasive cleaners Rinse the glass thoroughly Dry the glass completely Replace Broken Glass Immediately Do not operate your stove if the glass in the doors is damaged If you need to replace th...

Page 22: ...an end and pulling firmly 2 Use a wire brush or the tip of a screwdriver to clean the channel of any remaining cement or bits of gasket Fig 32 Remove stubborn deposits of cement with a cold chisel if...

Page 23: ...cantly However regular chimney inspection and maintenance must still be performed For safety good stove performance and to protect your chimney and chimney connector inspect your chimney and chimney c...

Page 24: ...and remove ash build up behind the com bustion package This should be done in conjunction with annual cleaning of the chimney connector since this inspection is most conveniently done through the flu...

Page 25: ...64 62 19 56 60 59 22 56 58 54 23 25 48 49 50 45 53 42 41 53 24 28 57 26 27 38 18 17 14 16 46 65 62 44 43 40 39 34 35 70 33 31 32 30 28 42 29 15 71 36 5 6 75 76 77 77 78 27 80 MHSC reserves the right...

Page 26: ...er Pin Ashdoor 30001749 33 Ashdoor Hinge Lower 30002404 34 Ashpan 1601025 35 Ashpan Bracket 1601039 36 Ashpan Cover 1601027 37 Airwash Manifold 30002407 38 Front See Chart Pg 33 39 Left Door See Chart...

Page 27: ...0002633 30002623 30002643 30003082 Right Side 30003053 30002612 30004877 30003063 30003073 30002632 30002622 30002642 30003083 Flue Collar 30003008 2324280 30004868 30003020 30003032 2374280 1324280 3...

Page 28: ...d wood chemically treated wood or any fuel not recommended in the Owners Guide 4 This warranty does not cover a stove repaired by someone other than a Vermont Castings Authorized Dealer 5 Damage to th...

Reviews: