11
Encore
®
1450CE Non-Catalytic Woodburning Stove
30003845
connecting flue pipe - clearances
Single wall connecting fluepipes can reach extremely
high temperatures; therefore, clearances from the con-
necting fluepipe (chimney connector) must comply with
the requirements of Part J of Building Regulations 000
(Combustion Appliances and Fuel Storage Systems).
This can be achieved by following the recommenda-
tions of Approved Document ‘J’. These are as shown in
Figure 13.
34
FLUEPIPECLEARANCES
D
at least
3 x D
elevation
without
Shield
elevation
with Shield
at least
3 x D
at least
1.5 x D
at least 1.5
x D
plan without
Shield
plan with
Shield
Air space of at least 1 mm
between noncombustible shield
and combustible material
Fluepipe
at least
1.5 x D
at least
1.5 x D
at least 3 x D
D
at least
1.5 x D
ST911
fig. 13
Connecting fluepipe clearances.