background image

Installation and 

Operating Instructions

Approved to ANSI Z21.60 / CSA 2.26

20304949  1/13  Rev. 2

WARNINGS

If the information in this manual is not followed 

exactly, a fire or explosion may result causing 

property damage, personal injury or loss of 

life.

–  Do  not  store  or  use  gasoline  or  other 

flammable vapors and liquids in the vicinity 

of this or any other appliance.

–  WHAT TO DO IF YOU SMELL GAS
  •  Do not try to light any appliance.

  •  Do not touch any electrical switch; do not 

use any phone in your building.

  •  Immediately  call  your  gas  supplier  from 

a  neighbor's  phone.  Follow  the  gas 

supplier's instructions.

  •  If you cannot reach your gas supplier, call 

the fire department.

–  Installation and service must be performed 

by a qualified installer, service agency or the 

gas supplier.

Vented Gas Log Set

Model: VDY24/18

This gas log set is to be installed only in a 

solid-fuel burning  fireplace with a working flue 

constructed of noncombustible material.

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future refer-

ence.

4949

VDY log cover

Summary of Contents for DUZY VDY24/18

Page 1: ...e Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your ga...

Page 2: ...r Placement 12 Decorative Volcanic Rock Placement 12 Fireplace Draft Test 12 contents Flame Appearance 13 Initial Startup 13 Operating Instructions 14 For Your Safety Read Before Lighting 14 Millivolt...

Page 3: ...zard of high surface temperature and should stay away to avoid burns or clothing ignition 11 Young children should be carefully supervised when they are in the same room with the gas log set in opera...

Page 4: ...hutoff valve Piping which complies with local codes Pipe wrench Tee joint Pipe sealant approved for use with propane L P G Resistant to sulfur compounds Drill with masonry bit for mounting to the floo...

Page 5: ...re of the fireplace damper blade and provide a minimum flue opening per table below Should the clamp not fit or provide the required permanent opening from the table have the damper blade cut to pro v...

Page 6: ...in the homeowner s manual must not be exceeded NOTE If the log set is equipped with a remote receiver a restrictive barrier may reduce the battery life by increasing the ambient temperature inside th...

Page 7: ...pe Internally tinned copper or copper tubing can be used per National Fuel Code section 2 6 3 providing gas meets hydrogen sulfide limits and where permitted by local codes Gas piping system must be s...

Page 8: ...cause improper and dan gerous operation Verify proper operation after servicing WARNING The Millivolt thermopile is a self powered combination gas control that does not require 110VAC to operate See F...

Page 9: ...k covering The remote receiver is attached but does not physi cally fit inside the fireplace with 2 clearance to the side wall install remote receiver Connect wires according to remote receiver instru...

Page 10: ...e 8 LG1000 VDY2418D5 BACK LOG Back Log 1 LG1000 Figure 9 LG1001 VDY2418D5 bottom logs Bottom Left Log 3 Bottom Right Log 2 LG1001 Figure 10 2 Placed bottom right log 2 on right side of grate Figure 10...

Page 11: ...d middle right log Figure 11 5 Place middle right log 5 on top of bottom right log Figure 11 6 Rest top right log 6 on back log and bottom right log Figure 12 7 Place top left log 7 on bottom left log...

Page 12: ...is important to periodically clean and inspect the logs per the cleaning and ser vicing section of the manual FIREPLACE DRAFT TEST FIREPLACE DRAFT TEST METHOD To determine if your fireplace is draftin...

Page 13: ...pilot flame must always be present when appliance is in operation It should touch the thermocouple or ther mopile body Initial Startup During manufacturing fabricating and shipping various components...

Page 14: ...pplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never...

Page 15: ...ntrol knob in for a further 60 seconds to prevent the flame detector from shut ting off the gas while the probe is warming up Release the control knob 9 Turn gas control knob counterclockwise to the O...

Page 16: ...lure to keep air intake holes clean will result in sooting and poor combustion If embers rock wool have turned a rust color and become brittle remove old embers rock wool from log set Replace with new...

Page 17: ...2 Pilot is partially clogged 3 Defective thermopile 1 Gas leak 2 Control valve defective 1 Gas supply turned off or manual shutoff valve closed 2 Control knob not in PILOT position 3 Control knob not...

Page 18: ...s clogged or dam aged 2 Burner is damaged 3 Gas regulator is defective 1 Vapors from paint or curing process of logs 1 Turning control knob to HIGH posi tion when burner is cold 2 Air in gas line 3 Di...

Page 19: ...07 2 Control Knob 18D0603 18D0603 3 Millivolt Control Valve w Pilot 27D8006 27D8005 4 Pilot 27D8974 27D8973 5 Thermocouple Thermopile 28D0566 28D0566 ACCESSORIES Flex Connector Flexcon30 Wall Kit Swit...

Page 20: ...2418D5 logs REPLACEMENT PARTS DUZY V LOG SERIES Ref Description Qty VDY24 18D5 1 Back Log 1 32D3121 2 Bottom Right Log 1 32D3122 3 Bottom Left Log 1 32D3123 4 Middle Left Log 1 32D3124 5 Middle Right...

Page 21: ...21 Duzy Gas Log Sets The Look and Feel of a Real Wood Fire 20304949...

Page 22: ...days to comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed Massachusetts Residents...

Page 23: ...s The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox b...

Page 24: ...Technical Service Costco Bilingual 1 800 463 3783 Vermont Castings Group 1 866 500 5670 Vermont Castings Group 149 Cleveland Drive Paris Kentucky 40361 www vermontcastingsgroup com...