INSTALLER / CONSUMER 

SAFETY INFORMATION

30002008  3/06  Rev. 6

PLEASE READ THIS MANUAL 
BEFORE INSTALLING AND USING 
APPLIANCE.

WARNING!

IF THE INFORMATION IN THIS 
MANUAL IS NOT FOLLOWED 
EXACTLY, A FIRE OR EXPLOSION 
MAY RESULT CAUSING PROPER-
TY DAMAGE, PERSONAL INJURY 
OR LOSS OF LIFE.

FOR YOUR SAFETY

Installation and service must be per-
formed by a qualified installer, service 
agency or the gas suppler.

WHAT TO DO IF YOU SMELL 

GAS:

• 

Do not try to light any appliance.

• 

Do not touch any electric switch; do 
not use any phone in your building.

• 

Immediately call your gas supplier 
from your neighbor’s phone. Follow 
the gas supplier’s instructions.

• 

If you cannot reach your gas supplier, 
call the fire department.

DO NOT STORE OR USE GASO-
LINE OR OTHER FLAMMABLE 
VAPORS AND LIQUIDS IN THE 
VICINITY OF THIS OR ANY OTHER 
APPLIANCE.

This appliance may be installed in an 
after market permanently located manu-
factured (mobile) home where not pro-
hibited by local codes.

This appliance is only for use with the 
type of gas indicated on the rating plate.

This appliance is not convertible for use 
with other gases unless a certified kit is 
used.

Dutchwest

Natural Vent Gas Heater

Models: 2467, 2468

Homeowner’s Installation 

and Operating Manual

INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER

CERTIFIED

DESIGN

CERTIFIED

2008

Dutchwest

gas stove

cover

6/03

Summary of Contents for Dutchwest 2467

Page 1: ...om your neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the re department DO NOT STORE OR USE GASO LINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE...

Page 2: ...rements 6 Vent Layout and Height Requirements 6 Passing Through a Combustible Wall or Ceiling 7 Venting Requirements 7 Install the Optional Fan 8 Venting System Assembly 9 Connect the Gas Supply Line...

Page 3: ...venting system WARNING Operation of this heater when not con nected to a properly installed and maintained venting system or tampering with the vent safety shutoff system can result in carbon monoxid...

Page 4: ...lve Inlet C L Valve Inlet 2008 Dutchwest NV dimensions 6 23 03 17 419 mm 23 584 mm 28 721 mm 4 111 mm 6 172 mm 12 318 mm 24 622 mm See Page 5 for Flue Collar Centerline Dimensions Fig 1 Dutchwest dime...

Page 5: ...m clearance to combustible materials Maintain a 6 152 mm clearance when using single wall pipe The gas appliance and vent system must be vented directly to the outside of the building and never be att...

Page 6: ...at a Type B vent system rising on the outside of the home be enclosed in a chase Check your local codes for requirements The minimum vent system height for the Dutchwest Natural Vent Stove is 8 2 43 m...

Page 7: ...o 36 feet 12m in height Up to an 18 ft horizontal vent run can be installed within the vent system using a maximum of two 90 degree elbows or four 45 degree elbows B Vertical installations up to 36 fe...

Page 8: ...snapstat bracket Use needle nose pliers to remove the black plastic grommet from the bracket Discard the bracket Connect the two wires to the two snapstat extension leads pro vided with the parts bag...

Page 9: ...e rebox Use a B vent adapter from the same maker as the rest of the B vent components to join the rst section of venting to the draft hood The stove includes a spill switch Operating this stove when n...

Page 10: ...f 10 0 and a mini mum inlet supply pressure of 11 0 w c In the U S Gas connection should be made in ac cordance with current National Fuel Gas Code ANSI Z223 1 NFPA 54 Since some municipalities have a...

Page 11: ...ig 19 Attach switch assembly to rear shroud PILOT ADJ TP TH TPTH ST228 attach switch wires to valve 12 99 ST228 Fig 20 Attach switch wires to valve Install the Log Set 1 Remove the logs from their pac...

Page 12: ...engage with the corresponding ribs at the bottom When properly installed the bottom of the stove front cannot be pulled away from the sides without also lifting it ST773 handle assy 6 6 03 3 8 Lock in...

Page 13: ...iate the condition Pilot and Burner Inspection Each time you light your heater check that the pilot ame and burner ame patterns are as shown in Fig ures 26 and 27 If ame patterns are incorrect turn th...

Page 14: ...ING smell all around the heater area for gas Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor WHAT TO DO IF YOU SMELL GAS Do not try to light any replac...

Page 15: ...burner lights wires are faulty or connections are bad B Thermopile may not gen 1 Be sure wire connecitons from thermopile at gas ate suf cient voltage valve terminals are tight and thermopile is full...

Page 16: ...il the operation of the converted appliance is checked as speci ed in the manufacturer s instructions supplied with the kit CAUTION The gas supply shall be shut off prior to disconnecting the electric...

Page 17: ...l s Starting at 5251 ST718 Fig 33 Natural gas air shutter setting ST726 SNV air shutter lp gas position 8 23 02 djt 1 8 3 8 Air Shutter LP Position Air Shutter LP Position Con guration for Stove with...

Page 18: ...Rear Part Minimum Maximum Setting 000 5022 69 029 30000513 54 055 20000130 21 500 28 000 3 8 Open Conversion to Natural Gas Input BTU h Air Shutter Kit Front Part Rear Part Minimum Maximum Setting 00...

Page 19: ...ture stove paints available through your local dealer to touch up areas as needed Clean areas to be painted with a wire brush and be sure to cover the logs burner and valve assembly glass and frame as...

Page 20: ...upply before inspecting the system Both the inner exhaust pipe and the outer combustion supply pipe must be checked to con rm that they are unblocked and in good condition Check the Gas Flame Regularl...

Page 21: ...Rheostat Chassis Ground RHEOSTAT SNAPSTAT BOX Snapstat BLK B L K BLK BLK BLK WHT ST153 rdv connections diag 10 99 Fig 42 Fan circuit MOTOR SNAPSTAT ON OFF RHEOSTAT WHT WHT BLK BLK BLK GRN BLK ST236 F...

Page 22: ...s 30002005 4 Grille NV DW Gas 30002044 5 Front DW Gas 30001928 6 Door DW Gas 30001929 7 Leg DW Gas 30001930 1a 1b 1c PILO T ON OFF PILOT ADJ L O H I 15a b 16 17 18 21 20 28 25 26 27 30a b 23a b 31 32...

Page 23: ...6 22a Ori ce Hood 69 0 0292 Front LP 30000513 22b Ori ce Hood 54 Front Natural 20000130 22c Or ce Hood 54 Rear LP 20000130 22d Or ce Hood 44 Rear NG 30000334 23a Ori ce Pilot 62 NG Top Convertible 100...

Page 24: ...rolled by a snapstat that turns power on and off as the rebox tem perature rises above and falls below a preset tempera ture A rheostat provides for variable fan speeds Speci cations 115 Volt 60Hz 75...

Page 25: ...25 Dutchwest Natural Vent Gas Heater 30002008...

Page 26: ...26 Dutchwest Natural Vent Gas Heater 30002008...

Page 27: ...stomer s home or in the dealer s shop Ifuponinspection thedamageisfoundtobethefaultofthemanufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or componen...

Page 28: ...Ef ciency Ratings Model EnerGuide Ratings Fireplace Ef ciency 2467 51 4 2468 51 4 2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation...