20
8390-975
Vermont Castings • Defiant® Model 1975-CAT-C Installation Manual_R8 • 02/21
ST540
Assembly
handle
11/00
Figure 3.8
- Assemble the front door handle.
ST635
Encore
Install thermostat
handle
2/01
Figure 3.7
- Attach the thermostat handle.
E. Attach Damper Handle
Use the 1/4"-20 x 3" screw to attach the damper handle to
the damper stub on the left side.
F. Install Catalyst Temperature Probe
To install the catalyst temperature probe, remove the hole
plug from the cast iron wall behind the rear shield, Figure 3.6.
Use two #10 sheet metal screws and bracket supplied, secure
the bracket and probe to the back of your stove, Figure 3.6.
H. Assemble the Removable Insert Handle
The wooden removable insert handle opens and closes the
front doors. Remove after each use, and store it in the handle
holder behind the right front leg. Assemble the handle by
passing the 3-3/8" screw through the wooden shaft and into
the bright metal nub, Figure 3.8. Tighten carefully until snug.
G. Attach Primary Air Thermostat Handle
The primary air thermostat handle is the smaller of the two
black handles. Secure the handle to the stub on the right
side of the stove with an 8-32 x 2" slot head machine screw,
Figure 3.7.
WARNING
!
The flue collar heat shield must be installed in all vertical
installations. The flue collar heat shield is not used when
the flue collar is in the rear exit position.
C. Adjust the Leg Levelers
Lift the stove slightly so there is no weight on the leg while
making the adjustment.
D. Reverse Flue Collar (If necessary)
Reverse the flue collar by removing the two screws that attach
it to the back of the stove. Be sure the gasket around the
flue collar opening is in position when you screw the collar
back onto the stove.
Figure 3.6
- Install the Catalyst Temperature Probe
1.4"
1.8"
Bracket mounting screw hole location
Fold bracket strap over
catalyst probe shaft
and secure with screw.
Insert catalyst probe
through sheetmetal and
cast iron back and twist &
push through fiber panel.
Remove hold plug
from cast iron back.
Insert catalyst probe bracket
with self-drilling screw.
Figure 3.5
- Install flue collar heat shield.
ST1180
flue collar heat shield
Sheet Metal
Screws
Sheet Metal
Screws
Flue Collar
Heat Shield