17
8390-975
Vermont Castings • Defiant® Model 1975-CAT-C Installation Manual_R8 • 02/21
Distance from the Center of the Flue Collar to the Wall in Top-Exit Installations
The information on this page is helpful in planning stove placement for top-exiting installations, particularly those installations
with chimneys that pass through the ceiling. However, this is not a clearance chart. Final stove clearances must adhere to
the guidelines stated in the clearance chart on Page 14.
Dimensions indicated are valid for installations with either 6" or 8" flue collars.
Double Wall Connector
Side (A)
Rear (B)
Corner (C)
Side (D)
Rear (E)
Corner (F)
36-1/2" (927 mm)
21" (533 mm)
16" (406 mm)
20-1/2" (521 mm)
9" (229 mm)
16" (406 mm)
ST511
Defiant
Flue Centerline
Diagrams
04/19
*
A
B
C
*
D
E
F
* This distance, from the center of the flue collar to the front edge of the hearth, is the same for all installations on this page:
34" (865 mm) in the United States and 36" (914 mm) in Canada.
Single Wall - No Connector Heat Shields
Unprotected Surface
Protected Surface
Parallel Installations
Corner
Installations
Parallel Installations
Corner
Installations
Side (A)
Rear (B)
Corner (C)
Side (D)
Rear (E)
Corner (F)
36-1/2" (927 mm)
21" (533 mm)
16" (406 mm)
20-1/2" (521 mm)
9" (229 mm)
16" (406 mm)