14
Defiant
®
1975 Non-Catalytic / Catalytic Woodburning Stove
30005220
Defiant clearance chart for 6” and 8” connections oNly
Stove clearance
Stove installed parallel to wall
Unprotected Surface
protected Surfaces
1
No connector heat Shields
with connector heat Shields
Side
Rear
2
corners
Side
Rear
2
corners
Stove installed parallel to wall
Stove
in
corner
Stove
in
corner
The attached rear shroud must be used in all installations. The flue collar heat shield must be used in all vertical installations.
1. The connector pipe heat shield must extend 36” (914 mm) above the flue collar.
2. WARNING: If stove has been installed based on the clearances described above as “Top exit with single wall or double wall
connector pipe,” then stove cannot be operated as “Door open with fire screen and damper open” without moving the stove so
the clearance meets those described for this type installation.
3. Using a listed double wall oval to round connector.
A ceiling heat shield, 24” (610 mm) in diameter and suspended 1” (25 mm) from the ceiling must surround the pipe in installations
where the chimney penetrates the ceiling.
(to rear
(
to back edge
(to rear (to back edge
shroud)
of cast top)
shroud)
of cast top)
Top exit with single
(A) 21”
(B) 15”
(C) 21”
(D) 5”
(E) 5”
(F) 3”
(G) 9”
(D) 5”
wall connector pipe
(521 mm)
(381 mm)
(521 mm)
(127 mm) (127 mm) (76 mm)
(229 mm)
(127 mm)
Door open with fire
screen used and
(H) 22”
(I) 18”
(J) 24”
damper open
(559 mm)
(457 mm)
(610 mm)
n/a
n/a
n/a
n/a
n/a
(8” chimney only)
2
Top Exit with double
(P) 21”
(Q) 15”
(R) 21”
(S) 5”
(T) 5”
(U) 3”
(V) 9”
(W) 2”
wall
3
connector pipe
(521 mm)
(381 mm)
(521 mm)
(127 mm) (127 mm) (76 mm)
(229 mm)
(51 mm)
Rear Exit
(X) 21”
(Y) 10”
(Z) 16”
n/a
n/a
n/a
n/a
n/a
(521 mm)
(254 mm)
(407 mm)