D. Tools And Supplies Needed

Before beginning the installation be sure the following tools 

and building supplies are available:

E. Inspect Appliance and Components

•  Remove appliance and components from packaging and 

inspect for damage.

•  Report to your dealer any parts damaged in shipment.

•  Read all the instructions before starting the installation. 

Follow  these  instructions  carefully  during  the 

installation to ensure maximum safety and benefit.

To minimize the effects of negative air pressure:

•  Install the outside air kit with the intake facing prevailing 

winds during the heating season

•  Ensure adequate outdoor air for 

all combustion appliances 

and exhaust equipment

•  Ensure furnace and air conditioning return vents are not 

located in the immediate vicinity of the appliance

•  Avoid installing the appliance near doors, walkways or 

small isolated spaces

•  Recessed lighting should be a “sealed can” design

•  Attic hatches weather stripped or sealed

•  Attic mounted duct work and air handler joints and seams 

taped or sealed

•  Basement installations should be avoided 

• Reciprocating saw 

• Framing material

• Pliers 

• 

High temp caulking material

• Hammer 

• Gloves

• Phillips screwdriver 

• Framing square

• Flat blade screwdriver 

• Electric drill and bits

• Plumb line 

• Safety glasses

• Level 

• Tape measure

• Misc. screws and nails

• 1/2-3/4 in. length, #6 or #8 self-drilling screws

•   Installation and use of any damaged appliance. 
•   Modification of the appliance.
•   Installation other than as instructed by Hearth & Home 

Technologies.

•   Installation  and/or  use  of  any  component  part  not 

approved by Hearth & Home Technologies.

•   Operating  appliance  without  fully  assembling  all 

components.

•  Operating with the front doors open.
•  Operating appliance without legs attached (if supplied 

with appliance).

•  Do NOT Over fire - If appliance or chimney connector 

glows, you are over firing.

Any such action that may cause a fire hazard.

Fire Risk.

Hearth & Home Technologies disclaims any 

responsibility for, and the warranty will be 

voided by, the following actions: 

WARNING

!

Fire Risk

Inspect appliance and components for 

damage. Damaged parts may impair safe 

operation.

•  Do NOT install damaged components.
•  Do NOT install incomplete components.
•  Do NOT install substitute components.
Report damaged parts to dealer.

WARNING

!

When this room heater is not properly installed, a house 

fire  may  result.  To  reduce  the  risk  of  fire,  follow  the 

installation  instructions.  Contact  local  building  or  fire 

officials  about  restrictions  and  installation  inspection 

requirements in your area.

WARNING

!

Summary of Contents for Aspen C3

Page 1: ...any other appliance Do not over fire If appliance or chimney connector glows you are over firing Over firing will void your warranty Comply with all minimum clearances to combustibles as specified Failure to comply may cause house fire Installation and service of this appliance should be performed by qualified personnel Hearth Home Technologies recommends HHT Factory Trained or NFI certified profe...

Page 2: ...Certification 3 B BTU Efficiency Specifications 3 C Mobile Home Approved USA Canada 3 D Glass Specifications 3 E Non Combustible Materials 4 F Combustible Materials 4 G California Safety Information 4 2 Getting Started A Design Installation Considerations 5 B Fire Safety 5 C Negative Pressure 5 D Tools And Supplies Needed 6 E Inspect Appliance and Components 6 F Install Checklist 7 3 Dimensions an...

Page 3: ... with 8 copper ground wire and chimney must be listed to UL103 HT or a listed UL 1777 full length six 152mm diameter liner must be used Outside air must be installed in a mobile home installation D Glass Specifications This appliance is equipped with 5mm ceramic glass Replace glass only with 5mm ceramic glass Please contact your dealer for replacement glass EPA Certification Number EPA Certified E...

Page 4: ...ifornia to cause cancer and carbon monoxide which is know to the State of California to cause birth defects or other reproductive harm For more information go to www P65Warnings ca gov G California Safety Information H Smoke CO Detectors Safety Tips Smoke and CO Detectors The use of smoke and carbon monoxide CO detectors throughout the home is strongly advised even if not required by building code...

Page 5: ...d be given serious consideration 1 Install at least one smoke detector on each floor of your home to ensure your safety They should be located away from the heating appliance and close to the sleeping areas Follow the smoke detector manufacturer s placement and installation instructions and be sure to maintain regularly 2 Getting Started Check building codes prior to installation Installation MUST...

Page 6: ...ulking material Hammer Gloves Phillips screwdriver Framing square Flat blade screwdriver Electric drill and bits Plumb line Safety glasses Level Tape measure Misc screws and nails 1 2 3 4 in length 6 or 8 self drilling screws Installation and use of any damaged appliance Modification of the appliance Installation other than as instructed by Hearth Home Technologies Installation and or use of any c...

Page 7: ...ured in place with proper clearance Chimney meets recommended height requirements 16 Feet Roof flashing installed and sealed Terminations installed and sealed Clearances Combustible materials not installed on non combustible areas Verified all clearances meet installation manual requirements Mantels and wall projections comply with installation manual requirements Protective hearth strips and hear...

Page 8: ...ew 15 381 mm 25 1 16 637 mm 16 406 mm 23 1 2 597 mm 24 1 4 616 mm Aspen C3 Specs 01 04 19 ts 24 1 2 623 mm 27 3 16 691 mm 15 381 mm 25 1 16 637 mm 16 406 mm 23 1 2 597 mm 24 1 4 616 mm 6 1 4 159 mm 7 1 2 191 mm Aspen C3 Specs 01 04 19 ts 24 1 2 623 mm 27 3 16 691 mm Figure 3 2 Side View 25 1 16 637 mm 23 1 2 597 mm 24 1 4 616 mm 6 1 4 159 mm 7 1 2 191 mm Aspen C3 Specs 01 04 19 ts 24 1 2 623 mm 27...

Page 9: ...ear A Figure 3 4 Figure 3 5 Supporting timbers under fireplace hearths are considered to be combustible Comb Floor Dia 01 07 19 ts Wood framing requires protection from radiant heat Fireplace Hearth Protection For all fireplace installations follow the floor protection guidelines described above Keep in mind that many raised hearths will extend less than the required clearance from the front of th...

Page 10: ...m B Back Wall to Appliance 3 76 mm C Side Wall to Vent Pipe 18 457 mm D Back Wall to Vent Pipe 5 1 2 140 mm Vertical Vent Horizontal Exit Description Single Wall Pipe A Side Wall to Appliance 14 356 mm B Back Wall to Appliance 8 203 mm C Side Wall to Vent Pipe 18 1 2 470 mm D Back Wall to Vent Pipe 11 279 mm E Minimum Vertical 0 0 mm F Minimum Floor to Ceiling 84 2134 mm G Minimum Vent Pipe to Cei...

Page 11: ... clearances Fireplace Clearances A fireplace installation requires special clearance between the side of the stove and the right and left walls the side of the stove and the decorative side trim on the fireplace face and the top of the stove and the mantel Maximum Mantel depth A Figure 3 10 of a combustible mantel is 9 230 mm At that depth the clearance to the stove top B must be a minimum of 22 1...

Page 12: ... should Install through the warm space enclosed by the building envelope This helps to produce more draft especially during lighting and die down of the fire Penetrate the highest part of the roof This minimizes the affects of wind turbulence and down drafts NOTICE Locating the appliance in a basement or in a location of considerable air movement can cause intermittent smoke spillage from applianc...

Page 13: ... diameter of the chimney can affect draft and cause poor performance It is not recommended to use offsets and elbows at altitudes above 4000 feet above sea level and or when there are other factors that affect flue draft 3 ft 91 cm Minimum Less than 10 ft 305 cm 2 ft 61 cm 3 ft 91 cm Minimum 10 ft 305 cm To Nearest Roofline 2 ft 61 cm Pitched Roof Figure 3 13 10 ft 305 cm or more 3 ft 91 cm Minimu...

Page 14: ...keep it warm Single Venting Each airtight stove requires its own flue If an airtight stove is vented to a flue that also serves an open fireplace or a leakier stove it s easier for the chimney draft to pull air in through those channels and performance of the stove suffers Imagine a vacuum cleaner with a hole in the hose to understandtheeffecthere Insomecasestheotherappliance can even cause a nega...

Page 15: ... chimney can be new or existing masonry or prefabricated and must meet the following minimum requirements specified in section 4C Chimney Systems C Chimney Systems Prefabricated Metal Chimney Must be minimum 6 152 mm diameter ID high temperature chimney listed to UL 103 HT 2100 F or ULC S629M Must use components required by the manufacturer for installation Must maintain clearances required by the...

Page 16: ...framing lumber to fit into wall opening Inside opening of frame should be no less than 14 x 14 356 mm x 356 mm Figure 4 4 Attach the wall spacer to the chimney side of the frame 5 Nail the frame into the wall opening The spacer should be on the chimney side 6 Insert the section of the solid insulated chimney into the outer wall of the masonry chimney 7 Tightly secure the length of the solid insula...

Page 17: ...ion consult a qualified installer service agency or your dealer WARNING Flue Gas Direction Crimped End Toward Appliance Secure pipe sections with a minimum of 3 screws Figure 4 7 Chimney Connector Appliance Pipe Fire Risk Follow Chimney Connector Manufacturer s Instructions for Proper Installation ONLY use connector WARNING Within the room between appliance and ceiling or wall Connector shall NOT ...

Page 18: ... the remaining two legs with hex bolts and washers 5 Appliance Set Up Carefully tilt the stove on the shipping brackets to install one front and one rear leg Then tilt the stove up on those legs to install the remaining two Figure 5 1 Install legs on one side of stove then the other Installation and use of any damaged appliance Modification of the appliance Installation other than as instructed by...

Page 19: ...UCH AS AN ATTIC OR GARAGE CAUTION 2 The stove must have a permanent connection to the outside to supply combustion air 3 A listed chimney system including roof thimble spark arrestor chimney supports roof flashing and any other components suitable for use in mobile homes must be used The chimney system must comply with the standard for Chimneys Factory Built Residential Type and Building Heating A...

Page 20: ...nt operating and maintenance instructions included Leave this manual with party responsible for use and operation Read understand and followtheseinstructions for safe installation and operation DO NOT DISCARD This product may be covered by one or more of the following patents United States 5341794 5263471 6688302 7216645 7047962 or other U S and foreign patents pending We recommend that you record...