Page 1: ...AC41 Door Access Controller ...

Page 2: ...ting screws and wall anchors What you ll need A working wired internet connection over ethernet A smartphone or laptop A 2 Phillips screwdriver or power drill with a 2 Phillips driver bit 5 16 inch 7 9mm drill bit for wall anchors 5 32 inch 4mm drill bit for pilot holes A Cat5 or Cat6 ethernet cable ...

Page 3: ... AC41 Overview AC41 Wall mount Power cable exit Power cable exit Cable mangement box Wall mount security screws Access control cable exit Access control cable exit Door contact switch Door security screw ...

Page 4: ...Status LED Door status LED Dry 12V 24V selection switch Toggle between doors Active door Test lock Test DPI Test REX Dual USB 2 0 Power Dual Ethernet Power supply monitor Removeable cassette AC41 Details ...

Page 5: ...9 AC41 Cassettes Remove all 5 cassettes from their packaging and insert into the AC41 Ensure the USB C and other mating features are aligned for correct fitment ...

Page 6: ...11 AC41 Mounting To remove the wall mount unscrew the two security torx screws from the inside ...

Page 7: ...enclosure Drill four 5 16 Ø holes into the wall Insert the drywall anchors into the holes Fasten the mount plate onto the wall by installing the mounting screws into the wall anchors Drill four 5 32 Ø holes into the wall Fasten the mount plate onto the wall by installing the mounting screws into the pilot holes ...

Page 8: ...14 mount mount 15 Place the sheet metal enclosure over and onto the mounting plate tabs Fasten the two security torx screws to secure the enclosure to the mounting plate ...

Page 9: ...17 AC41 Connect Door The AC41 comes equipped with a Form C relay that can be driven dry or wet AC41 is rated to power 12V locks up to 700mA and a 24V locks up to 350mA ...

Page 10: ...or cassette from the AC41 by lifting it from the side tabs Connect the Lock Dry LOCK positive 12V 24V goes into NC fail safe or NO fail secure LOCK power supply goes into COM Lock Lock power supply 12V 24V GND Lock Lock power supply 12V 24V GND ...

Page 11: ... connect door connect door 21 Connect the Lock Wet 12V 24V NC C If you have a Fail Safe lock connect to NC COM Connect the Lock Wet 12V 24V NO C If you have a Fail Secure lock connect to NO COM Lock Lock ...

Page 12: ... door connect door 23 Connect the Reader Verkada AD31 reader far left port Connect the Inputs Door Position Indicator Door Contact optional Standard Wiegand readers middle input port Request to Exit REX optional ...

Page 13: ...1 Connect Connect the AC41 to your network using either of the Ethernet ports located at the bottom of the controller If you are adding an additional AC41 unit to your system you can connect ACUs by Ethernet ...

Page 14: ...anaging doors but cannot reach the server Solid blue Controller is managing doors and connected to the server Status LED Connect AC41 to Ethernet Plug in your AC41 to an AC outlet Go to www verkada com start For detailed installation instructions visit www verkada com support Connect the AC41 power supply into your standard power outlet 120 VAC ...

Page 15: ...e selected door by clicking Trigger Lock Pressing the Door button will cycle which door is selected for testing Emulate the DPI or REX by clicking Emulate To make installation easier the AC41 has four buttons to help test or emulate different events ...