Use the top down, bottom up method to connect storage shelves to the appliance.
The general scheme follows.
■
The appliance is connected to the first storage shelf with one SAS-3 cable.
■
One cable connects the first storage shelf to the next shelf.
■
Subsequent storage shelves are connected until the last storage shelf is
connected.
■
The last storage shelf is connected to the appliance with one cable.
■
The last storage shelf is also connected to the next, highest, storage shelf.
■
The storage shelves are connected until the shelf closest to the appliance is
connected.
About IPMI configuration
The Intelligent Platform Management Interface (or IPMI) provides management and
monitoring capabilities independently of the host system's CPU, firmware, and
operating system. You can configure the IPMI sub-system for your appliances. You
can use the remote management port, located on the rear panel of the appliance,
to connect to the IPMI sub-system.
The following figure shows the remote management port (or the IPMI port) on the
rear panel of a NetBackup 5240 appliance:
IPMI
The IPMI is beneficial after an unexpected power outage shuts down the connected
system. In case the appliance is not accessible after the power is restored, you can
use a laptop or desktop computer to access the appliance remotely by using a
network connection to the hardware rather than to an operating system or login
13
Hardware overview
About IPMI configuration
Summary of Contents for NetBackup 5240
Page 4: ......
Page 22: ...Preinstallation requirements Prerequisites for IPMI configuration 22 ...
Page 42: ...Installation procedures Connecting a 4TB appliance to more than one storage shelf 42 ...
Page 43: ...43 Installation procedures Connecting a 4TB appliance to more than one storage shelf ...
Page 66: ...Installation procedures Accessing and using the Veritas Remote Management interface 66 ...