Warning:
Confirm that all power to the devices is turned off to prevent personnel
injuries and to prevent damage to the devices.
Verify that the devices and cables are installed correctly. The following table provides
instructions for checking the device installation.
Table 6-1
Installation confirmation
Incorrect installation
Correct installation
Component
The storage shelf is
insecurely mounted or
mounted too high within the
rack cabinet.
The storage shelf is placed securely
in the lowest portion of the rack
cabinet.
Veritas Storage Shelf
The appliance is insecurely
mounted or mounted too high
within the rack cabinet.
The appliance is placed securely in
the lower portion of rack cabinet,
above the storage shelf or shelves.
NetBackup appliance
Only one power cable is
connected to the device.
The AC power cables of the
appliance and all storage shelves
are connected to the power
modules and the AC power supply.
AC power cables
One or both SAS cables fail
to connect the two RAID ports
in the appliance to the two
SAS_IN ports in the storage
shelf.
The SAS cables connect the two
RAID ports in the appliance to the
two SAS_IN ports in the storage
shelf.
SAS cables
One or both SAS cables fail
to connect the second
storage shelf to the first
storage shelf.
SAS cables connect the two
SAS_IN ports in the second shelf
to the two SAS_OUT ports in the
first shelf. Subsequent shelves are
connected in the same manner.
SAS cables for more
than one storage shelf,
if used
Turning on the storage shelves
These steps should be followed in the given order when turning on the devices for
the first time.
Caution:
You must turn on each storage shelf
before
you turn on the NetBackup
appliance. When the storage shelves have initialized, proceed to turn on the
appliance.
Verifying the operation of the appliance and configuring IPMI
Turning on the storage shelves
46