background image

VER0006101V00

Summary of Contents for EcoWifi 1.000W

Page 1: ...VER0006101V00 ...

Page 2: ... Power supply 4 D Operating instructions 4 Modes 4 Adjust programmed temperatures 5 Setting program and time day 6 Setting program 6 Setting the time and day 7 Keypad locking 7 Advanced engineer settings 7 Reset radiators 8 Default settings 8 E F A Q 9 Error messages 9 F Eco Design 9 INFORMATION 10 1 Very important 10 2 Wall mounting 10 3 Guarantee 11 Index ...

Page 3: ...nnot be put into a normal bin For further information get in touch with your local council or the supplier who you purchased this product Very Important It is possible that the radiator may make slight sounds during the first days of operation This is quite normal in dry radiators and can occur when the aluminium elements expand and contract Please note there is no danger to the user Children unde...

Page 4: ...have a plug on the supply cord installation should be carried out by a qualified electrician Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules of the country where it is to be installed Before connecting check the supply is switched off Before connecting the appliance to the fixed wiring check that the voltage of supply is inside the rated values ...

Page 5: ...mode the temperature of each hour will change automatically following the programmed Schedule The user must assign to each hour one of the next temperatures mode Comfort used normally when the user is at home Eco or saving used at night or for brief absence periods Freeze or minimum temperature used for longer absence periods To define these temperatures Press Prog will display the right temperatu...

Page 6: ...inimum temperature for long absence periods Represented by no bar at LCD Press the Prog key for 3 seconds to start programming settings You can switch directly to the day and time setting by pressing Prog again Setting program 1 The display will show 00 00 on day 1 2 With the mode key select the desired temperature mode for that time Comfort eco o míni mum 3 Use the key to increase the value of th...

Page 7: ... minutes and exit the time and day settings In case the device is already associated with a control unit the time setting is cancelled and the time of the control unit is automatically set Keypad locking Use this function to prevent any changes to your settings In a child room public area etc Press and for 3 seconds to lock at the LCD the Lock message will appear Pres and for 3 seconds to unlock A...

Page 8: ...edule so the user do not need to take into account the time needed to heat the room Maximum anticipation time 24h Indicated with the symbol 4 To select one of the three advanced settings C1 to C5 use the keys 5 Choose the required mode by pressing mode 6 Press buttons to change 7 Press mode or Prog to confirm and exit Reset radiators Press simultaneously mode and Prog for 10 seconds The figure on ...

Page 9: ...rol plus day timer no Electronic room temperature control plus week timer yes Other control options multiple selections pos sible Room temperature control with pre sence detection no Room temperature control with open window detection yes With distance control option yes With adaptative start control yes With working time limitation yes With black bulb sensor no Contact information see back cover ...

Page 10: ... remove from the top of the box the radiator comes in Please follow the illustrated steps below to hang and install your radiator 1 Take the radiator out of its packaging and choose where to hang it Please note the minimum dis tances required around the heater 1 2 The flap of the box has the guide printed on it to place the radiator on the wall You must make the holes of the template to Drill and ...

Page 11: ...oblems arising from installing an undersized heater not enough heat improper installation etc are not covered by this guarantee This heater is for domestic light commercial use only installation in any another enviroment voids this guarantee VeriSmart Heating Limited reserves the right to decide whether to repair or replace any defective part or to replace the entire heater All costs arising from ...

Page 12: ...VeriSmart Heating Limited Postal Address Unit 12085 PO Box 4336 Manchester M61 0BW Email info verismartheating com Call 01484 213 151 ...