NOTICE

•  This product is not intended for life or safety applications.

•  Do not install this product in hazardous or classified locations.

•  Read and understand the instructions before installing this product.

•  Turn off all power supplying equipment before working on it.

•  The installer is responsible for conformance to all applicable codes.

If this product is used in a manner not specified by the manufacturer, the protection 

provided by the product may be impaired. No responsibility is assumed by the 

manufacturer for any consequences arising out of the use of this material.

Installation Guide

Air Quality

Product Identification

Product Overview

The CWV2 air quality sensor for living space is for use with BAS controllers designed to accept 4 to 20mA,  
0 to 5 Vdc or 0 to 10 Vdc outputs. This sensor measures CO2 levels using a dual-beam, non-dispersive infrared (NDIR) 
technology. 

The CWV2 Value sensor with an accuracy of ±40 ppm ±5.5% of measured value, is ideal for bid-spec applications. 

CWV2

Value Wall Mounted Air Quality Sensor

Specifications

OPERATING ENVIRONMENT

Input Power

Class 2; 20 to 30 Vdc, 24 Vac, 50 to 60 Hz

Max. Current

45 mA

Analog Output

Selectable 4 to 20 mA, 0 to 5 V, 0 to 10 V

Operating Temp. Range

0 to 50 °C (32 to 122 °F)

Operating Humidity Range

0 to 95% RH non-condensing

Housing Material

High-impact ABS plastic

Terminal Block Torque

0.5 to 0.6 N-m (0.37 to 0.44 in-lbf)

CO2 TRANSMITTER

Sensor Type

Dual-beam, non-dispersive infrared (NDIR), diffusion sampling

Output Range

0 to 2000 ppm

Accuracy

±40 ppm ±5.5% of measured value

Repeatability

±30 ppm ±4.5% of measured value

Response Time

≤75 seconds for 90 degree step

WIRING TERMINALS

Terminal Blocks

Screw terminals, 18-24 AWG

Screw Terminal Torque

0.2 N-m (2.0 in-lbF) max.

WARRANTY

Limited Warranty

1 year

COMPLIANCE INFORMATION

Agency Approvals

UL 916, European conformance CE: 
     EN61000-6-2
     EN61000-6-3
     EN61000 Series - industrial immunity    
     EN 61326-1
FCC Part 15 Class B, REACH, RoHS, RCM (Australia), ICES-003 (Canada)

CWV2

CWV2

Summary of Contents for CWV2

Page 1: ...ving space is for use with BAS controllers designed to accept 4 to 20mA 0 to 5 Vdc or 0 to 10 Vdc outputs This sensor measures CO2 levels using a dual beam non dispersive infrared NDIR technology The CWV2 Value sensor with an accuracy of 40 ppm 5 5 of measured value is ideal for bid spec applications CWV2 Value Wall Mounted Air Quality Sensor Specifications OPERATING ENVIRONMENT Input Power Class2...

Page 2: ...ion Guide Dimensions Functions 115 4 5 85 3 3 24 0 9 The CWV2 sensor measures CO2 and temperature if equipped in a room and provides analog outputs to a controller 1 Remove the cover from the base at the bottom of the device 2 Position the sensor base vertically on the wall 1 35 m 4 5 ft above the floor with the UP arrow facing upward Locate away from windows vents and other sources of draft If po...

Page 3: ...rcompanies trademarksareherebyacknowledgedtobelongtotheirrespectiveowners CWV2 Installation Guide 4 Mount the backplate onto the wall using the screws provided Six screw holes available Use a minimum of two for secure mounting Connect the wires to the screw terminals Do not over tighten the screws CWV2 wiring diagram 5 4 3 2 1 COMMON CO2 OUT POWER 24 5 Set the DIP switches ON 1 2 3 4 5 6 7 8 mA Vo...

Page 4: ...usedwithvoltageoutputmodeenabled 6 With sensor base fully installed align top of cover to mounting tabs on top of sensor base Swing cover downward until it latches at the bottom 7 Install locking screw to secure cover in closed position China RoHS Compliance Information 本表格依据SJ T11364的规定编制 O 表示该有害物质在该部件所有均质材料中的含量均在GB T 26572规定的限量要求以下 X 表示该有害物质至少在该部件的某一均质材料中的含量超出GB T 26572规定的限量要求 企业可在此处 根据实际情况对上表中打...

Reviews: