Orbis

INSET LIVE FUEL-EFFECT GAS FIRES

User Instructions

These instructions should be read by the user before operating the

appliance and retained for future reference

Model No’s NVICC**MN, NVICC**SN & NVICC**RN are only for use on

Natural Gas (G20) at a supply pressure of 20 mbar in G.B. / I.E.

** denotes trim and fret variant fitted to product

Summary of Contents for Orbis NVICC**MN

Page 1: ...tructions should be read by the user before operating the appliance and retained for future reference Model No s NVICC MN NVICC SN NVICC RN are only for use on Natural Gas G20 at a supply pressure of...

Page 2: ...I S 813 1996 Domestic Gas Installation which is issued by the National Standards Authority of Ireland Any purpose made ventilation should be checked periodically to ensure that it is free from obstruc...

Page 3: ...ler and that during the service the fire is removed from the fire opening and the chimney or flue visually checked for fallen debris or blockages which must be removed The chimney should also be check...

Page 4: ...ely event of a failure of the igniter the fire can be lit as follows Depress the control knob and turn anti clockwise to the position marked pilot Hold in the control knob for a few seconds to allow t...

Page 5: ...the unlikely event of a failure of the igniter firstly check the operation of the 1 5V battery and if necessary replace with a AA size alkaline battery It is impor tant that only an alkaline battery...

Page 6: ...o reduce the level of heat input on the fire point the handset at the fire and press the small flame button once An audible beep will be heard and the heat input level will reduce to the low setting 4...

Page 7: ...will now remain in the off position until activated by the remote handset Fig 2 REPLACING THE BATTERIES REMOTE CONTROL MODELS ONLY ENSURE THE FIRE IS COOL BEFORE REPLACING BATTERIES Remove the ashpan...

Page 8: ...re that the fire has been allowed to fully cool CLEANING THE TRIMS AND PAINTED METAL PARTS Dependent upon the trim option chosen for use with this fire there is a variety of methods that can be chosen...

Page 9: ...uelbed base is located centrally in the fire box Ensure that the fuelbed base fit fully down onto the fuel bed support and is not lodged on the burner See fig 3 below Fig 3 b Position the two halves o...

Page 10: ...ramic rail as a guide for placement See fig 5 below Fig 5 d Select two of the large square coals two of the large random coals and arrange behind the front row of coals ensuring that flame paths as in...

Page 11: ...second row of coals using the ribs in the fuelbed matrix as a guide for placement See fig 7 below Fig 7 f Select the remaining two large square coals and two random coals and position to fill the gaps...

Page 12: ...lled as RCF waste This is not classified as hazardous waste and may be disposed of at a tipping site licensed for the disposal of industrial waste Protective clothing is not required when handling the...

Page 13: ...rts are as follows these are available from Verine Fires who may be contacted at the address shown on the rear cover Fuelbed base B 58690 Fuelbed front rails L H R H B 18730 Replacement coal set B 120...