Verilink 41TDM Configuration Manual Download Page 1

Specifications

Network Interface

Service Type:

DDS-I or DDS-II clear 
channel

Operating  Modes: Full duplex, point-to-point, 

multi-point

Line Rate:

56 and 72 kbps 

Loop Range:

Up to 45 dB of loss

Line Connection:

RJ-48C jack, 8-pin 
modular

Timing Source:

DDS-I: Network, Internal
DDS-II: Network

Antistream Timer: Off, 10, 30, or 60 seconds

Supervisory Port 

Connection:

8 - pin modular (RS-232) 

Data Rates: 

1.2, 2.4, 9.6, and 19.2 kbps

SLIP Port 

Connection:

8 - pin modular (RS-232) 

Data Rates: 

1.2, 2.4, 9.6, and 19.2 kbps

Ethernet (option) 

Connection:

8 - pin modular 

Network Protocol: TCP / IP-based networks

Data Rate:

10 Mbps

Compatibility:

10BASE - T, ISO/IEC 
8802-3

Token Ring (option) 

Connection:

8 - pin modular (RJ-45) 

Network Protocol: TCP / IP based networks 

Data Rate:

4 or 16 Mbps

Compatibility:

Type 3 UTP, ISO/IEC 
8802-5 

Dial Backup

Connection:

6-pin modular

Backup Service:

ISDN, sync

Configuration:

Information for backup 
unit is stored in unit and 
transmitted to backup unit 
by inband AT commands.

Dialing:

Numbers programmed and 
stored in unit and 
transmitted to backup unit 
by inband AT commands.

Restoral:

Manual or automatic restoral 
to leased line service

Diagnostics

Loopbacks:

V.54 (send and receive), 
alternating loop (DDS-I), 
latching loop (DDS-II)

BERT:

511 pattern 

Alarms

Activation:

Programmable thresholds

Reporting:

Front panel LEDs, call out 
on alarm (COA),  SNMP 
TRAPs 

Power

115 VAC:

116 mA, 8 W max, 
27 BTU max

Mechanical

Housing:

Plastic standalone case

Mounting:

Desktop or horizontal rack 

Dimensions:

12 inches (30.40 cm) wide
2 inches (5.08 cm) high
9 inches (22.86 cm) deep

Weight:

4 pounds (1.814 kg)

Environmental

Storage Temp:

32

°

 to 122

°

F (0

°

 to 50

°

C)

Operating Temp:

4

°

 to 185

°

F (

20

°

 to 85

°

C)

Humidity:

95% maximum (non -

condensing)

Compatibility

TR 62310:

November 1987

TR 62310A:

December 1989 
(addendum 3)

TR 41450:

November 1981

Internet Standards: RFC 1157 (SNMP)

RFC 1155 (SMI)
RFC 1213 (MIB-II)
RFC 1055 (SLIP)
Enterprise TXPORT MIB
Enterprise DDS MIB

DDS -I Port Data Rates

Standard mode

Port A: 

Sync onlyat 56 kbps 

Port B:

Inactive 

Proprietary, non-TDM mode

Port A: 

Sync at 2.4, 4.8, 9.6, 19.2, 
38.4, or 52 kbps 

Async at 2.4, 4.8, 9.6, 
19.2, 38.4, or 57.6 kbps

Port B:

Inactive 

Proprietary, TDM mode

Port A: 

Sync at 2.4, 4.8, 9.6, 19.2, 
or 31.2

*

 kbps 

Async at 2.4, 4.8, 9.6, 
19.2, or 31.2

*

 kbps

Port B: 

Sync at 2.4, 4.8, 9.6, 19.2, 
or 31.2

*

 kbps 

Async at 2.4, 4.8, 9.6, 
19.2, or 31.2

*

 kbps

*

Only one port can be set for 31.2 kbps at a 

time. If Port A is set to 31.2 kbps, Port B is lim-
ited to 19.2 kbps. If Port B is set it 31.2 kbps, 
Port A is limited to 19.2 kbps.

DDS -II Port Data Rates

Standard mode

Port A: 

Sync only at 64 kbps 

Port B:

Inactive 

Proprietary, non-TDM mode

Port A: 

Sync at 2.4, 4.8, 9.6, 19.2, 
38.4, 56, 60 kbps 

Async: at 2.4, 4.8, 9.6, 
19.2, 38.4, 56, 57.6 kbps

Port B:

Inactive 

Proprietary, TDM mode

Port A: 

Sync at 2.4, 4.8, 9.6, 19.2, 
or 38.4

*

 kbps 

Async at 2.4, 4.8, 9.6, 
19.2, or 38.4

*

 kbps

Port B: 

Sync at 2.4, 4.8, 9.6, 19.2, 
or 38.4

*

 kbps 

Async at 2.4, 4.8, 9.6, 
19.2, or 38.4

*

 kbps

*

Only one port can be set for 38.4 kbps at a 

time. If Port A is set to 38.4 kbps, Port B is lim-
ited to 19.2 kbps. If Port B is set it 38.4 kbps, 
Port A is limited to 19.2 kbps.

Connections

SUPV/SLIP and DDS Pinout

Port A and Port B Pinouts

Pin SUPV/SLIP

DDS

1

DTR Out

Data Out (Tip)

2

RTS Out

Data Out (Ring)

3

Frame  Gnd

4

Data Out 

5

Data In 

6

Signal Gnd

7

CTS In 

Data In (Tip)

8

DCD In 

Data In (Ring)

ITU Ckt Name

V.35

RS-232 EIA-530 DCE

101/AA

Frm Gnd

A

1

1

Gnd

102/AB

Sgnl Gnd B

7

7

Gnd

103/BA

TxD

P, S

2

2, 14

In

104/BB

RxD

R, T

3

3, 16

Out

105/CA

RTS

C

4

4, 19

In

106/CB

CTS

D

5

5, 13

Out

107/CC

DSR

E

6

6, 22

Out

108/CD

DTR

H

20

20, 23

In

109/CF

DCD

F

8

8, 10

Out

114/DB

TC

Y, AA 15

12, 15

Out

115/DD

RC

V, X

17

9, 17

Out

141/LLB LL

18

18

In

140/RLB RL

21

21

In

142/TM Test Mode

25

Out

45-00129

4.0

41TDM

Configuration Guide

SCROLL

EXIT

SELECT

TDM

TEST ALARM POWER

PRISM 41TDM

T

R

A

N

S

P

O

R

T

®

LAN

SLIP

SUPV

DDS

DBU

PORT  A

PORT  B

115VAC
50/60Hz

116ma