Veria Control T45

Installation guide

EN

Summary of Contents for Control ET45

Page 1: ...Veria Control T45 Installation guide EN ...

Page 2: ...ctionality Select how to control your floor heating system 6 Recommended settings 7 Setting the clock 8 Setting the maximum floor temperature 8 Reading the floor temperature 9 Frost protection mode 9 Timer functionality Activate Timer Mode 10 Programming the timer 10 Technical specifications 14 Veria Warranty 15 EN ...

Page 3: ...loor heating system by either the floor temperature the room temperature or combined Please follow the instructions in this manual to ensure many years of trouble free usage Congratulations with your new Veria floor heating system Please notice that the thermostat must be installed by an authorized electrician ...

Page 4: ...and display description Current room temperature Heating element warming Day of the week Thermostat on On off Down Up Clock Mode Current floor temperature EN Timer mode activated Frost protection mode activated ...

Page 5: ...crew in properly sized screws into the wall socket wall box When proberly fastend and cables connected see diagram below mount the frontpanel to the backpart again Electrical wall box socket Wiring diagram Remote sensor Mains voltage 85 240V ra IP ting IP30 S1 L Load S2 L N Load N 13A Max load Temperature 0T30 Veria ApS Ulvehavevej 61 DK 7100 Vejle Denmark Model Veria Control T45 85 240V Max 13A E...

Page 6: ...ement turns on off around a room temperature setpoint the temperature shown in the display is the actual room temperature Combined floor and room temperature program modes 3 5 The heating element turns on off around a room tempera ture setpoint with a requested max floor temperature floor temperature is prioritized over room temperature Change between the above floor heating modes With the thermos...

Page 7: ...m sensor If total effect 0W 1840W x 2 floor sensor If total effect 0W 2990W x x 3 combined floor and room sensor If total effect 1840W 2990W x x 4 room sensor If total effect 1840W 2990W x 5 combined floor and room sensor If total effect 0W 1840W x x Top flooring made of parquet laminate massive wood carpet linolium or the like Top flooring of tiles concrete marble or the like EN ...

Page 8: ...s function is used for wooden floors mainly and is only available in program modes using the floor sensor program mode 3 and 5 The temperature setting should be maximum 35C which is also the default set point of the thermostat If you choose to control the floor temperature solely by the floor sensor program mode 2 the max floor temperature is set for 35C and can t be changed Change the floor tempe...

Page 9: ... program mode 1 and 4 room sensor the display always shows the current room temperature FROST PROTECTION MODE To enable frost protection mode With thermostat turned off Press M for 3 seconds Select 01 00 disabled When enabled and thermostat has been turned off the heating will be activated if the room floor temperature is lower than 5 C the heating will be stopped if the room floor temperature is ...

Page 10: ... need to select Programmable function and the display must show see above You can now set the heating programs The thermostat must have 4 heating periods for the weekdays and 4 heating periods for the weekend Please notice that the programming of the whole calendar week must take place in one continuous process so it is a good idea to have the periods written down for reference when programming th...

Page 11: ...mperature setting 18C Example weekend Period 1 staring at 09 00 Temperature setting 22C Period 2 staring at 23 00 Temperature setting 18C Period 3 staring at 23 01 Temperature setting 22C Period 4 staring at 23 02 Temperature setting 18C My settings Week days Period 1 on C Period 2 on C Period 3 on C Period 4 on C Weekend Period 1 on C Period 2 on C Period 3 on C Period 4 on C Timer functionality ...

Page 12: ... 4 for the weekday you are now able to set the switching times for weekend Sa Su will be displayed Use Up Down key to set the required start time Press to accept this setting Use the Up Down key to set the required temp Repeat for switching times 2 4 for the weekend To disable the timer select Override Mode 01 How to override settings in TIMER MODE At any time you can change the preset timer tempe...

Page 13: ...13 EN Notes ...

Page 14: ...11 2 kOhm Display LCD Power consumption 2W Set point range Room 5 C to 35 C Floor 20 C to 35 45 C Accuracy 1 C Buttons Touch pad Switch current rating 13A resistive load Mains voltage 85 240V Dimensions 86 x 86 x 13 mm WxHxD Fixing screw width 60mm Housing ABS PC Flame Retardent Operating rating 0 30 C 5 95 RH non con densing EN ...

Page 15: ...Electrician installer Thermostat name Installation date Article number Stamp Stamp Please notice In order to obtain the Veria warranty an authorized electrician installer must fill in the below fields Name Telephone Address Zip code City EN ...

Page 16: ...0114 EN Veria Ulvehavevej 61 7100 Vejle Denmark E mail mail veria dk ...