3.0 2132 Controller
3.3.1
Setting the Timer Mode
Scroll to 'tm.OP'; use
or
to view and alter the mode. The mode shows as 'OPt.1'
to 'OPt.5'.
It is not possible to alter the mode while the timer is operating; if the mode cannot be
altered, scroll to the 'StAt' parameter and set its value to OFF.
3.3.2
Setting the Time Period
Method 1
Scroll to 'tmr' (time remaining). Use
or
to view the remaining time; the units are
always in minutes. Use
or
to set or alter the time. Setting 'tmr' automatically
activates the timer; the 'm-A' parameter changes to 'Auto' and the 'StAt' parameter
changes to run.
Note that the 'tmr' display shows 0 (zero) during the last minute of timing and also
shows 0 when the time has expired. The timer light indicates whether timing is still in
progress.
Method 2
Scroll to 'dwEll' and use
or
to set the timing duration. The advantage of method 2
is that 'dwEll' need only be set once if repeated use of the same time period is required.
Scroll to 'StAt' and use
or
to set the parameter value to run. This copies the dwell
time into 'tmr' and activates the timer as in method 1.
3.3.3
Running with the Timer
Once the timer is activated by method 1 or 2 above, the control sequence depends on
the 'Timer' mode, as previously given in the table. Fig 3 gives another representation of
the timer action.
14
Summary of Contents for CARBOLITE GERO VMF-ASTM
Page 4: ...10 2 Power Settings 38 11 0 Specifications 39 11 1 Environment 39 4 ...
Page 20: ...3 0 2132 Controller 3 7 Navigation Diagram 20 ...
Page 28: ...6 0 Maintenance Power Consumption Measure the current drawn on each phase cir cuit 28 ...
Page 40: ......
Page 41: ...Notes Service Record Engineer Name Date Record of Work ...