Mast Maintenance
The mast on the PCMS unit has the signboard and the solar panels attached. On most units a
hydraulic pump system that is connected to the batteries in the battery box, raises and lowers
the mast. However some smaller units rely on a manual hand winch to raise and lower the
mast.
9.1
Mast Periodic Maintenance
Item
Function Required
Before
Each Use
3 Months
12 Months
Mast
Mast
Check for leaks (hydraulic fluid) on the
ground under the mast.
•
•
•
Raise mast to full height and check Nylatron
runners and screws.
Clean any build-up.
Adjust for snug fit on mast.
•
Check main bolt (top of mast) is tight.
•
Check bolts at the bottom of the mast are
tightened at 64 ft.-lb (86.8 N.m.)
•
Check all metal parts for rust and corrosion.
Lubricate lightly.
•
Frame Welds
Check for cracks and/or failures.
•
•
•
9.2
Hydraulic Lift System for Mast
NOTE
For safety during transport Ver-Mac disconnects power to the hydraulic pump.
Make sure the power feed is connected to the battery terminals inside the battery
compartment.
9.2.1
Raising and Lowering the Mast
NOTE
Before raising or lowering the mast, open battery box and check that the
hydraulic bypass valve is tight.
1. To raise mast, open control box, and flip switch to Sign Up.
The mast rises automatically.
2. To lower mast, reverse the procedure.
The hydraulic system used to raise and lower the mast does not require any
regularly scheduled maintenance beyond periodic checking of the fluid.