![VER-MAC PCMS-1500 Operation, Safety And Maintenance Manual Download Page 51](http://html1.mh-extra.com/html/ver-mac/pcms-1500/pcms-1500_operation-safety-and-maintenance-manual_1003077051.webp)
Battery Bank
Give us your thoughts
Ver-Mac 2019
PRO Series PCMS Operations, Safety & Maintenance V2
45
12.5 Battery Bank Periodic Maintenance
Item
Function Required
Before
Each Use
3 Months 12 Months
Batteries
Battery Bank
Inspect outside of battery
(damage, cracking and leaking fluid)
Replace any leaking battery
immediately
•
•
•
Inspect water level*
Fill as needed
•
•
•
Test with voltmeter
(fully charged 12.7 V or higher) Charge as
needed
•
•
•
Test with Hydrometer*. Check specific
gravity does not vary more than 0.05 units
between cells
•
•
Inspect terminals for corrosion, tightness of
connections
Clean as necessary
•
•
Boxes
Inspect for damage, water infiltration
•
Check that cover closes and locks securely
•
•
*Deep-charge batteries only.