Disconnect the fan from power mains prior to any connection, servicing and repair operations. Mounting and 
maintenance are allowed for duly qualified electricians with valid electrical work permit for electric operations 
at the units up to 1000 V after careful study of the user's manual.   
The single-phase power mains must comply with the acting local electrical norms and standards.  
The fixed electrical wiring must be equipped with an automatic circuit breaker. The fan must be connected to 
power mains through an automatic circuit breaker QF integrated into the fixed wiring system with the gap 
between the breaker contacts on all poles not less than 3 mm.  
Check the fan for any visible damages of the impeller and the casing before starting installation. The casing 
must be free of any foreign objects that could damage the impeller blades.  Misuse of the device or any 
unauthorized modifications are not allowed.
The fan is not to be used by children and persons with reduced physical, mental or sensory capacities, without 
proper practical experience or expertise, unless they are controlled or instructed on the product operation by 
the person(s) responsible for their safety. Do not leave children unattended and do not let them play with the 
product. 
Take steps to prevent ingress of smoke, carbon monoxide and other combustion products into the room 
through open chimney flues or other fire-protection devices. Sufficient air supply must be provided for proper 
combustion and exhaust of gases through the chimney of fuel burning equipment to prevent back drafting. 
Transported medium must not contain any dust or other solid impurities, sticky substances or fibrous materials.  
Do not use the fan in the environment containing hazardous or explosive materials and vapours, i.e. spirits, 
gasoline, insecticides, etc. Do not close or block the fan intake or extract vents in order to ensure the most 
effective air passage. 
Do not sit on the fan and do not put objects on it.  
Fulfil the requirements stated in the user's manual to ensure long service life of the product. 

Recycle at the end of the service life.  

Do not dispose the product with unsorted municipal trash. 

!!

WARNING!

2

EN 

Summary of Contents for VENTS VK

Page 1: ...2013 www ventilation system com model VENTS VK EN CENTRIFUGAL FANS user s manual ...

Page 2: ...al mental or sensory capacities without proper practical experience or expertise unless they are controlled or instructed on the product operation by the person s responsible for their safety Do not leave children unattended and do not let them play with the product Take steps to prevent ingress of smoke carbon monoxide and other combustion products into the room through open chimney flues or othe...

Page 3: ... U U1 fan with a speed controller and electronic thermostat equipped with a built in temperature sensor and a power cable with adapter fig 11 VENTS VK XXX Un U1n fan with a speed controller and electronic thermostat equipped with an external temperature sensor fixed on 4 m cable a power cable with adapter fig 11 VENTS VK XXX P fan with a speed controller and a power cable with adapter fig 12 XXX s...

Page 4: ...odel fig 11 is equipped with an electronic speed controller with electronic thermostat TSC for automatic speed control air flow regulation depending on air temperature temperature based control logic VK U to maintain air temperature with accuracy to within 2 C The fan changes its speed rarely As air temperature rises up to the set thermostat point the fan switches to high speed As air temperature ...

Page 5: ... controller that enables switching the fan on off smooth speed air flow control from minimum to maximum value MOUNTING The fan is designed for both horizontal and top installation and may be mounted on the floor or attached to the wall or to the ceiling fig 2 While mounting the fan provide extra protection against water ingress The protection examples are shown in fig 2 1 For the top mounting posi...

Page 6: ...oduct as 24 months following the sale date via retail network subject to the customer s ensuring compliance with the rules of transportation storage mounting and operation of the product In case of any malfunction of the product through the fault of the Manufacturing company within the warranty period service life the customer shall have the right to elimination of the manufacturing defects by mea...

Page 7: ...ituting document in case of non timely technical maintenance of the product by the customer dust mud oil condensate foreign particles in case of causing external damage to the product by the customer damage shall not apply to external changes of the product required for the product mounting in case of altering the product design or further reworking of the product in case of replacing and using pa...

Page 8: ... responsible for defects arising after transferring the product to the customer and caused by the customer s violating the rules of transportation storage assembly and operation of the product or by actions of third persons an accident or force majeure circumstances The manufacturing company shall not be responsible for damage to health and property of the customer caused by the customer s violati...

Page 9: ...9 2 1 m 9 ...

Page 10: ...5 3 6 4 MOUNTING QF QF 10 ...

Page 11: ...8 7 11 ...

Page 12: ...0 125 150 200 250 315 21 22 23 24 25 26 27 28 29 min max tC 30 C 20 C speed control knob temperature control knob min max speed control knob N L X QF L N S N L X QF L N QF VK 100 125 150 200 250 315 U U1 Un U1n P R 12 ...

Page 13: ...13 14 13 ...

Page 14: ...14 17 15 18 16 15 15 ...

Page 15: ...15 15 20 19 ...

Page 16: ...08 Acceptance certificate 100 125 150 200 250 315 www ventilation system com VK The fan is duly recognized as serviceable VKS Q U U1 n R P Approval mark Sold Seller name and stamp Manufacturing date Date of sale ...