FAN SETUP 

    

on 

— interval timer turning on and adjustment is performed with the potentiometer 

T

on

. To turn the interval timer off 

set the potentiometer Ton into the leftmost position. Rotation of the potentiometer for 1/3 clockwise sets the interval timer 
operation for 6 hours, rotation of the potentiometer for 2/3 clockwise sets the interval timer operation for 12 hours, and 
rotation of the potentiometer clockwise in the rightmost position sets the interval timer operation for 24 hours.

off — To adjust the fan turn-off delay time, turn the control knob 

T

off

 clockwise to increase and counter-clockwise to 

decrease the turn-off delay time respectively, adjustable from 2 up to 30 minutes.

 — To adjust the humidity set point turn the control knob H clockwise to increase and counter-clockwise to decrease the 

humidity sensor set point, adjustable from 60 % up to 90 %.

WARNING! If the switch is turned off or the indoor humidity falls below the set point within 60 seconds after 
activation of the switch or the humidity sensor, the fan continues operation at low speed.

Terminal designations on wiring diagrams:

— phase

— 0

— external switch

QF 

— automatic circuit breaker

CAUTION! The fans rated for 12 V power voltage (stated on the packing box and on the fan casing) connect to 
12 V power mains only!

DO NOT USE A METAL SCREWDRIVER, KNIFE, ETC. FOR ADJUSTMENT 

OPERATIONS NOT TO DAMAGE THE CIRCUIT BOARD. 

Summary of Contents for Simple 100

Page 1: ...AXIAL FAN USER S MANUAL www ventilation system com VENTS 100 Simple EN ...

Page 2: ...6 Brief description 6 Operation guidelines 6 Designation key 7 Installation and setup 7 Fan setup 8 Electronics operation algorithm 10 Technical maintenance 11 Storage and transportation regulations 11 Manufacturer s warranty 12 ...

Page 3: ...was correct at the time of the document s preparation The Company reserves the right to modify the technical characteristics design or configuration of its products at any time in order to incorporate the latest technological developments No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means in any information search system or transla...

Page 4: ... that can damage the impeller blades While mounting the unit avoid compression of the casing Deformation of the casing may result in the motor jam and noisy operation Misuse of the unit and any unauthorised modifications are not allowed Take steps to prevent ingress of smoke carbon monoxide and other combustion products into the room through open chimney flues or other fire protection devices Suff...

Page 5: ...MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE DO NOT DISPOSE THE UNIT AS UNSORTED MUNICIPAL WASTE regarding safe use of the unit and understand the risks involved Do not allow children to play with the unit ...

Page 6: ...gn can also include a backdraft damper to prevent back flow when the fan is switched off The fan fits 100 mm air ducts OPERATION GUIDELINES The fan is rated for connection to single phase AC 230 V 50 Hz or 230 V 60 Hz power mains Air motion direction in the system must match the pointer on the fan casing Ingress protection rating against access to hazardous parts and water ingress is IP45 The fan ...

Page 7: ...with direct air exhaust to the ventilation shaft or into the round air duct of matching diameter Fig 2 Fan installation sequence Step 1 Cut off power supply and make sure electricity has been turned off Fig 4 Step 2 Run the power cable to the vent hole Fig 5 Step 3 Remove the front panel from the fan Then remove the terminal block cover Fig 6 Step 4 Mark and drill holes for mounting the fan and th...

Page 8: ...er clockwise to decrease the turn off delay time respectively adjustable from 2 up to 30 minutes To adjust the humidity set point turn the control knob H clockwise to increase and counter clockwise to decrease the humidity sensor set point adjustable from 60 up to 90 WARNING If the switch is turned off or the indoor humidity falls below the set point within 60 seconds after activation of the switc...

Page 9: ...0 Toff 2 min 30 min Ton Off 24 hour The fan delivery set includes a specially designed plastic screwdriver for fan settings adjustments Use it to change the turn on and turn off delay time and the humidity set point ...

Page 10: ...terminal S or if indoor humidity level H exceeds the set point adjustable from 60 to 90 After the control voltage is off or the humidity level has decreased the fan will keep running within the time set by the timer ranging from 2 to 30 minutes To set the maximum humidity setpoint 90 set the potentiometer to H max position To adjust the fan turn on delay time turn the control knob T clockwise to i...

Page 11: ...with temperature range from 5 C to 40 C and relative humidity up to 70 Storage environment must not contain aggressive vapours and chemical mixtures provoking corrosion insulation and sealing deformation Use suitable hoist machinery for handling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo Theunitcanbecar...

Page 12: ...ure its intended use by the user within the guaranteed period of operation The faults are eliminated by means of replacement or repair of the unit components or a specific part of such unit component The warranty repair does not include routine technical maintenance unit installation dismantling unit setup To benefit from warranty repair the user must provide the unit the user s manual with the pu...

Page 13: ...e unit warranty period Violation of the unit transportation regulations by the user Violation of the unit storage regulations by the user Wrongful actions against the unit committed by third parties Unit breakdown due to circumstances of insuperable force fire flood earthquake war hostilities of any kind blockades Missing seals if provided by the user s manual Failure to submit the user s manual w...

Page 14: ...14 EN ø 99 5 150 15 83 1 2 ...

Page 15: ...15 EN QF L N 3 4 5 6 7 8 9 10 11 ...

Page 16: ...16 EN 12 13 V T VT TH VTH QF 2 L N 3 S 60 90 H 2min 30min T 1 QF 2 L N 3 ...

Page 17: ...17 EN 14 60 90 H 2min 30min T 1 QF 2 L N 3 S 15 1 QF 2 L N 3 S 2min 30min T Jumper T VT TH VTH T1 ...

Page 18: ...18 EN QF L N 16 17 18 19 20 21 ...

Page 19: ...19 EN Quality Inspector s Stamp Manufacture Date Sold by name and stamp of the seller Purchase Date ...

Page 20: ...V171EN 01 Certificate of acceptance The fan is recognized as serviceable VENTS100Simple V K T T1 TH L Turbo 12 ...

Reviews: