background image

PU SENS 01 (A11)

PU SENS 01 (A19)

Sensor Control Panel

USER'S MANUAL

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for PU SENS 01 A11

Page 1: ...PU SENS 01 A11 PU SENS 01 A19 Sensor Control Panel USER S MANUAL All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 2: ...ument intended for technical maintenance and operating staff The manual contains information about purpose technical details operating principle design and installation of the PU SENS 01 unit and all...

Page 3: ...operations with wet hands Do not wash the unit with water Protect the electric parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains...

Page 4: ...OR SENSORY CAPACITIES OR THOSE WITHOUT THE APPROPRIATE TRAINING THE UNIT MUST BE INSTALLED AND CONNECTED ONLY BY PROPERLY QUALIFIED PERSONNEL AFTER THE APPROPRIATE BRIEFING THE CHOICE OF UNIT INSTALLA...

Page 5: ...Install the mounting box Remove the screws on the panel edge Disassemble the panel by separating the frontal part from the back part Pass the cable into the rectangular opening on the back part of the...

Page 6: ...e the battery use a new battery only 1 Disconnect the unit from power supply 2 Remove two screws in the bottom part of the casing 3 Pull the top part of the casing aside to allow access to the upper c...

Page 7: ...When the AUTO mode is active the unit switches to scheduled operation and ignores manual control settings of air flow and temperature provided that the timer is off 3 Manual control settings of air fl...

Page 8: ...the set level the unit slowly increases the speed If the room humidity is lower than the set level the unit slowly decreases the speed In this way the humidity is maintained at the set level The humi...

Page 9: ...ving changes press EXIT 5 User menu To enter the User menu press MENU in the control panel Main menu The User menu contains basic menu items and functions for parameters setting ENG MENU access to the...

Page 10: ...to the Engineering menu press EXIT If you forgot the user defined password see para 11 Password Change press and hold RESET until you hear a long sound signal 20 clicks approximately 20 seconds The de...

Page 11: ...the Engineering menu select the TEMPERATURE SENSOR submenu and press ENTER Select a desired sensor type Press ENTER to confirm To return to the Engineering menu without saving changes press EXIT The d...

Page 12: ...indoors BYPASS OPERATION MODES 1 automatic mode for set temperature maintenance and freeze protection 2 manual mode for positive air damper opening for natural ventilation The Summer Bypass only works...

Page 13: ...elect 0 deactivation of the unit 1 standby mode While in the Standby mode the ventilation unit runs at the first speed at the pre set temperature Press ENTER to confirm To return to the Engineering me...

Page 14: ...rol panel is installed The control panel is equipped with a humidity sensor Then use or to set the desired humidity level Press ENTER to confirm To return to the Engineering menu without saving change...

Page 15: ...enu without saving changes press EXIT The default settings are given in the table below 18 Current temperature review 6 15 20 OFF OFF Select the CURRENT TEMPERATURES item in the Engineering menu and p...

Page 16: ...ctive When the AUTO mode is active the unit switches to scheduled operation and ignores manual control settings of air flow and temperature provided that the timer is off To set up the AUTO mode press...

Page 17: ...00 12 00 1 20 2nd line 11 00 13 00 2 20 In the interval from 10 00 to 11 00 the unit will operate at the first speed and from 11 00 will switch to the second speed since the lower line has a higher p...

Page 18: ...the timer is active the unit switches to the timer scheduled operation and ignores the schedule settings AUTO mode and manual control settings AIR FLOW and TEMPERATURE Activation of the TIMER function...

Page 19: ...erval The OPERATING HOURS window shows the time elapsed from the filter installation Press RESET after replacement of the filter To save the changes and return to the Engineering menu press EXIT 23 Er...

Page 20: ...stment Operation 50 Sleep 1 Humidity setting Duct 50 Room 50 Temperature sensor correction 4 Timer settings Hours 01 Hour Minutes 00 Minute Air flow rate 1 Temperature 20 Motor hours Air handling unit...

Page 21: ...21 www ventilation system com All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 22: ...22 PU SENS 01 www ventilation system com All manuals and user guides at all guides com...

Page 23: ...23 www ventilation system com All manuals and user guides at all guides com...

Page 24: ...V55 6EN 10 All manuals and user guides at all guides com...

Reviews: