Vents Boost 150 User Manual Download Page 5

5

www.ventilation-system.com

DELIVERY SET

DESIGNATION KEY

PURPOSE

The product described herein is a mixed-flow inline fan for supply or exhaust ventilation of premises. The fan is designed for connection 
to ø 200 and 250 mm air ducts.
Transported air must not contain any flammable or explosive mixtures, evaporation of chemicals, sticky substances, fibrous materials, 
coarse dust, soot and oil particles or environments favourable for the formation of hazardous substances (toxic substances, dust, 
pathogenic germs).

Name 

Number

Fan 

1 pc.

User's manual 

1 pc.

Packing box

1 pc.

Plastic screwdriver (for the models with a timer) 

1 pc.

Boost

200 EC

R

Options
R

: cord with a mains plug

Un

: speed controller with an electronic thermostat and an outdoor temperature sensor 

fixed on a 4 m cord. Temperature-based operation logic

V

: three-position switch

S

: high-powered motor

T

: timer

P

: integrated smooth speed controller

Electric motor type
_

: asynchronous

EC

: electronically commutated

Air duct diameter [mm]

150, 160, 200, 250

Unit series

Inline mixed-flow fan

Summary of Contents for Boost 150

Page 1: ...Boost 150 Boost 160 Boost 200 Boost 250 Inline mixed flow fan USER S MANUAL...

Page 2: ...13 Installation certificate 13 Warranty card 13 This user s manual is a main operating document intended for technical maintenance and operating staff The manual contains information about purpose tec...

Page 3: ...on the unit and do not put objects on it The information in this user s manual was correct at the time of the document s preparation The Company reserves the right to modify the technical characterist...

Page 4: ...guard WARNING If there are any unusual oscillating movements immediately stop using the unit and contact the manufacturer its service agent or suitably qualified persons The replacement of parts of t...

Page 5: ...favourable for the formation of hazardous substances toxic substances dust pathogenic germs Name Number Fan 1 pc User s manual 1 pc Packing box 1 pc Plastic screwdriver for the models with a timer 1 p...

Page 6: ...ection rating against access to hazardous parts and water ingress is IP 4 The unit is rated as a class I electric appliance The unit design is constantly being improved thus some models may be slightl...

Page 7: ...traight air duct section to the spigots on both sides of the unit while mounting Minimum recommended straight air duct section length is equal to 3 fan diameters see the Technical data section If the...

Page 8: ...control voltage application to input terminal LT by an external switch e g indoor light switch After the control voltage is off the fan continues to operate within the set time period adjustable from...

Page 9: ...a section The connection must be made using durable insulated and heat resistant conductors cables wires The actual wire cross section selection must be based on the maximum load current maximum condu...

Page 10: ...arp objects as they may damage the impeller It is forbidden to remove or change the location of the balancers on the impeller as this can lead to increased level of vibration noise and reduce the serv...

Page 11: ...up after transportation at low temperatures allow the unit to warm up at operating temperature for at least 3 4 hours TROUBLESHOOTING Problem Possible reasons Troubleshooting The fan s do es not start...

Page 12: ...Seller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual includin...

Page 13: ...TE The _____________________________________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Techni...

Page 14: ...14 Boost www ventilation system com...

Page 15: ...15 www ventilation system com...

Page 16: ...V208 1EN_A4_stkr 03...

Reviews: