VENTILATORS VE30100 Installation And Operation Manual Download Page 1

Supersedes 8/15

i

WWW.CLEANCOMFORT.COM

VENTILATORS

IO-VENT-SS

7/17

IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. THIS GUIDE TO BE LEFT WITH EQUIPMENT OWNER.

MODELS: 
VH30100

  30-100 CFM HRV

 

VE30100

   30-100 CFM ERV

Features

•  Three operating modes  

(Intermittent, Continuous and High)

•  100% variable speed
•  Quick-connect duct collar system
•  Proportional defrost sequence
•  Single-person mounting system
•  Dual permanently lubricated PSC motors
•  Integral balancing taps in duct collars
•  Wall-mounting bracket included

VH30100 COMPACT  

HEAT RECOVERY VENTILATOR

VE30100 COMPACT ENERGY  

RECOVERY VENTILATOR

Installation and Operation Manual

Summary of Contents for VE30100

Page 1: ...V Features Three operating modes Intermittent Continuous and High 100 variable speed Quick connect duct collar system Proportional defrost sequence Single person mounting system Dual permanently lubricated PSC motors Integral balancing taps in duct collars Wall mounting bracket included VH30100 COMPACT HEAT RECOVERY VENTILATOR VE30100 COMPACT ENERGY RECOVERY VENTILATOR Installation and Operation M...

Page 2: ...ata of Daikin North America LLC Neither this document nor the information contained herein shall be reproduced used or disclosed to others without the written authorization of Daikin North America LLC except to the extent required for installation or maintenance of recipient s equipment Liability Notice Daikin North America LLC does not accept any liability for installations of ventilation equipme...

Page 3: ...se the ventilation system for removal of flammable fumes gases or connect directly to any appliances Do not modify repair or disassemble this system These tasks are to be performed by authorized serviced personnel only Fire electrical shock and or bodily injury may result if these warnings are not followed Always assess the operation of the ventilation system with regard to how it may interact wit...

Page 4: ...asement x 20 cfm 10 L s Single Bedroom x 10 cfm 5 L s Living Room x 10 cfm 5 L s Dining Room x 10 cfm 5 L s Family Room x 10 cfm 5 L s Recreation Room x 10 cfm 5 L s Other x 10 cfm 5 L s Kitchen x 10 cfm 5 L s Bathroom x 10 cfm 5 L s Laundry Room x 10 cfm 5 L s Utility Room x 10 cfm 5 L s TOTAL ventilation requirement add last column 1 CFM 0 47189 L s 1 L s 3 6 m3 hr B Air Change Per Hour Calculat...

Page 5: ...anch equivalent length 35 ft 10 7 m Round plastic diffuser equivalent length 100 ft 30 5 m NOTE Maximum airflow assumes diffuser is in full open position Tee take off equivalent length 50 ft 15 24 m Angle boot equivalent length 30 ft 9 14 m 90 perimeter pipe elbow equivalent length 10 ft 3 0 m NOTE Where flex duct is used to make 90 elbow equivalent length 20 ft 6 1 m Round wall cap spring damper ...

Page 6: ...nection to the forced air system return air duct is not less than 10ft 3 m upstream of the return plenum connection to the forced air system Check with your local building codes or the manufacturer of the forced air system The HRV and forced air system must be set to operate in continu ous mode to achieve maximum comfort and to avoid cross contamination Note to Installer Dwellings with multiple fo...

Page 7: ... cm Indirect Connection Breather Tee Important The duct bringing outdoor air to the return air plenum must be equipped with a manual damper to balance the outdoor airflow Important Building and combus tion appliance installation codes do not allow return air grilles or openings such as breather tee or indirect connections in an enclosed room that is susceptible to spillage of combustion appliances...

Page 8: ... to the unit with four 10 x 5 8 screws supplied in installation kit to ensure a proper seal See Figures 9 13 on following page Figure 5 Installation of the wall bracket Secure with two 10 x 11 4 screws Figure 6 Hang HRV ERV on the wall mounting bracket Figure 7 Before completing the installation make sure that the HRV ERV is level Figure 8 Secure HRV ERV to wall mounting bracket with the two 8 x 3...

Page 9: ...ED light on the unit s control is lit green but the unit s motors do not energize and the controls do not operate this indicates that the polarization in the main power supply outlet is inverted Correct polarity of supplied power before continuing with the installation Daikin recommends that the unit be connected to a dedi cated 120VAC receptacle use of an extension cord to power the unit is not r...

Page 10: ...idential applications of 110 CFM or less ONLY It must be installed in accordance with all current national and local regulation building and safety codes i WARNING Ensure the ventilation hood is installed with a minimum clearance of 6 ft 1 83 m away from the exhaust vents of a combustion source or a source of pollutants such as a gas furnace dryer gas boiler range hood barbecue garbage bin drivewa...

Page 11: ...L 4 strand to ensure proper connection Low Voltage Ventilator Controller Legend Field Installed Low Voltage Figure 18 Standard forced air wiring diagram R G B W G R B G R R W B G To Casing Screw for Ground R W B G Jumper JP 4 2 Relays 1 Relay LVC Version 1 LVC Version 2 Jumper JP 4 R G B W G R B G R R W B G To Casing Screw for Ground R W B G Jumper JP 4 2 Relays 1 Relay LVC Version 1 LVC Version 2...

Page 12: ...ket of each unit Figure 19 Alternate forced air wiring diagram Legend Field Installed Low Voltage Before wiring the ventilator to a forced air system always refer to system s manual or manufacturer i WARNING Always disconnect power to the unit prior to making any electrical connections Failure to disconnect the power could result in electrical shock or can damage the electronic boards wall control...

Page 13: ... speed even if the RH is above set point on the wall control or if a VHP T3 timer is activated INTER or CONT RH sensor dial set to OFF Ventilator does not run based on RH measured at the wall control sensor is disabled Otherwise the Ventilator and the wall control operates as described above and will go to high speed if a VHP T3 timer is activated In addition the VHP RD3P has the ability to operat...

Page 14: ...the fan speed selected for HIGH speed 2 When the LED stops flashing the ventilator is at its maximum speed Procedure for Setting High Override Airflow Rate and Balancing the Ventilator To balance the ventilator you will need to independently adjust the flow rate in both the fresh air supply duct as well as the stale air exhaust duct You will need an airflow measuring device such as a pitot tube or...

Page 15: ...w rates 11 To exit Balancing mode press the and buttons at the same time until the LED turns green indicating that the control has returned to Run mode Procedure for Setting Low Continuous Ventilation Rate When the unit is in Run mode the continuous airflow rate can then be set by using the and buttons and reading the CFM using the airflow measuring device 1 When the unit is in Run mode the contin...

Page 16: ... or noise Verify that the correct mounting equipment wall mounting bracket was used when hang ing the ventilator Verify that a section of flexible duct is installed between the ventilator and the rigid duct Verify that the motors are operating properly and the fans are rotating freely and are not obstructed by any debris Cold air Misplaced supply outlets Defrost not operating correctly The ventila...

Page 17: ...titive Install and service this equipment in compliance with applicable national and local building and safety codes 4 Clean the condensate drain and pan Twice a year check the condensate drain pan and tubing to ensure that they are open and free flowing The tubing can be disconnected for cleaning The condensate drain must have a trap in the tubing that traps a quantity of water and helps prevent ...

Page 18: ...IMPLIED OR OTHER CONTRACT BREACH NEGLIGENCE OR OTHER TORT Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion may not apply to you Any part replaced pursuant to this warranty is warranted only for the unexpired portion of the warranty term applying to the original part Warranties apply only to products installed in their ...

Page 19: ...WWW CLEANCOMFORT COM 19 IO VENT SS Notes ...

Page 20: ...VENTILATORS WWW CLEANCOMFORT COM 20 IO VENT SS Our continuing commitment to quality products may mean a change in specifications without notice 2015 Houston Texas Printed in the USA ...