11126 McCormick Road, Hunt Valley, MD 21031 | 800-851-4965 | [email protected] | ventevinfra.com |
Rev. 022822
28
5
Technical Data
Specification
CERTIFICATION
11 2 (1) GD Ex d [ia IIC Ga] IIB+H2 TS Gb
11 2 (1) GD Ex tb (ia Da] IIIC Tloo·c Db
MET Class I, II, Div 1, Groups B-G
MET Class I, II, Zone 1/21 Groups IIB+H2, Ill
POWER SUPPLY
120VAC or 230VAC ( /- 10%)
IEEE802.3at PoE
MAXIMUM POWER
CONSUMPTION
Basic Configuration:
25W
With Heaters:
125W
ENCLOSURE MATERIAL
Marine grade copper-free Aluminum light alloy epoxy powder coated
316L Stainless Steel (optional)
INGRESS PROTECTION
IP66
WEIGHT
Aluminum:
c. 30kg (hardware dependent)
316L Stainless Steel:
c. 70kg (hardware dependent)
DIMENSIONS
Aluminum:
415 x 315 x 250mm (16.34 x 12.4 x 9.84in)
316L Stainless Steel:
415 x 315 x 253mm (16.34 x 12.4 x 9.96in)
TEMPERATURE
Ambient temperature depends on variant, see order information
RELATIVE HUMIDITY
0 to 95%, non-condensing
INPUT CONNECTIONS
1 x AC power cable entry with screw terminals
1 x PoE power/ data 10/100/lOOOBase-T Ethernet on RJ45 socket
or
1 x Single or Multi mode fibre input on LC connector & Splice Tray
Note: MET enclosure entries are via
1/2”
NPT drilled entries all other variants are
via M20 x 1.5-6H drilled entries
ETHERNET LINK DISTANCE
10/100/l0OOBASE-T Ethernet on CAT6:
up to 100m
l000BASE-FX Multi Mode Fibre:
up to 2km, wavelength 1310nm
l000BASE-LXl0 Single Mode Fibre:
up to 10km, wavelength 1310nm
OUTPUT CONNECTION
Up to eight galvanically isolated N-Type RF outputs.
Note: It is the customer’s responsibility to ensure the maximum values for RF
Threshold power as per Table 4.0 of IEC 60079-0: 2011 are not exceeded. The
maximum RF output of the wireless transmitter and antenna gain must be taken
into account when installing equipment.