IMPORTANT INSTALLATION AND WARRANTY INSTRUCTIONS

 

 

MOUNTING

1.The unit may be mounted either between 
joists using the inbuilt clip fasteners or 
against a joist using a screw through the 

as a template. Place in the required location 
and mark out the hole cutting size. Hole 
size is 310mm x 300mm . 

2.Before commencing cutting ensure that 
the area behind the intended location is 
clear of all cables, pipes and joists. Once 
clear, cut out the section along the 
previously marked lines. 

3.Remove 4 heat lamps from the unit,then 
remove the plug of the led downlight 
inside the housing.Unfasten the fascia 
retaining spring clips inside the housing 
,and remove the fascia.Connet the 
ducting(if required) to the outer grill of the 
unit.Insert the unit into the square hole 
being sure to pull the side springs inward 
so that the body can pass through the hole 
without damaging the plaster. Ensure that 
the unit is held securely in place by the 
clips. If required, additional screws can be 
used to aid holding the unit in the ceiling. 

this purpose. 

4.Connect the led downlight plugs fristly 
.Hold the fascia against the body of the 
heater and the ceiling and attach the 
securing spring clips to hold the fascia in 
place. 

5.Now screw in the four large heat lamps 
into the lamp holder through the holes 
provided in the fascia. The globes should be 

electrical contact but don’t over tighten. 

1

2

5

3

4

Thank you and congratulations on your purchase of the 
Ventair 3 in1 Bathroom Fan, Heat & Light. Please read 
these instructions carefully before installing and using the 
product. Keep the instructions handy for future reference. 
Electrical wiring must only be done by a licensed 

issued completion of the installation.  

LOCATION

The unit must be located and installed in accordance with 
AS/NZS 3000 and local building codes and regulations 

The unit can be installed in any room that requires direct 

ceilings with a minimum height of 2.1 meters. At least 
250mm height clearance in the ceiling cavity is required 

The unit must also be installed at least 400mm away from 
the walls.
Ensure adequate inlets exist through windows, vents or 

POWER

AC220-240V, 50/60Hz electrical supply is required. The 
unit can be connected to a lighting or power circuit if 
loading permits. All electrical work must be carried out in 
accordance with AS/NZS 3000 or latest edition thereof.