Cautions

2. Ducting

Put one end of the 150mm diameter duct into the vent hole and connect to 

grill or cowl with one duct clip included . A 150mm diameter egg-crate grille 

is included in the package to be used when installing in soffit.  If installed 

in wall a weatherproof cowl should be used. Seal grille/cowl with suitable 

sealant.

Terminal

 Blocks

Dear customers,

Please read all instructions before commencing installation.

MANROSE FAN6577 

Halogen Heater Fan & Light

INSTALLATION

A few minutes of planning can make a big difference to the installation

time and also to your satisfaction with the function of the unit.

1. Cutting a vent

Locate the exterior grill location on a wall or soffit, then cut a 155mm

diameter hole at this very position.

3. Locating the bathroom heater, fan , light unit

For the purpose of obtaining the best heating effect from the lamps there 

should be at least 2.1 m overall height from unit to ground. The heater is 

most effective when you are

 

standing directly beneath it, so generally 

the unit would be mounted in a

 

place where you would stand to dry 

yourself.

 

For the exhaust fan to work

 

efficiently, replacement air of

Note: 

The length of each duct is 3.0m. Make sure that from the centre of 

installation position there should be a distance within 3.0m to the outside 

vent. 

7. Wiring

Connect one end of the interconnecting 

wire with the switch panel, and then 

drag the other end power cable out of 

the hole on the ceiling. Open the 

terminal block cover on the housing and 

make connection as the wiring diagram 

instructs, then reposition the terminal 

block cover. Tuck the excess wire into 

the ceiling so as to leave the housing 

enough room to fix in.

INSTALLATION INSTRUCTIONS AND HOLE-CUTTING TEMPLATE

Read and save these instructions!

Please use this card as hole cutting template 455mm x 305mm.

Wall venting shown

wall

sealant ventiduct

bathroom

heater

ceiling joist ceiling

fascia

duct clip

4. Prepare the ceiling

5. Remove the fascia

6. Disconnect

Power cables to LED Panel.

Remove 4 rubber clips at 2 ends of the rectangle air inlet grilles.

Heater Unit

Rubber clip

Air inlet grille

Glass shield

Screw behind rubber

Use this template to mark the hole outline on the ceiling. Make sure

a distance between the edges and wall is no less than 250mm. Also

from the rooftop should be a minimum 220mm height to the ceiling.

Remove the halogen heat lamp 

from the heater unit and keep it in 

a safe place. 

Do not touch 

 this

 

lamp with your bare skin.

Natural skin oils and salts damage new halogen lamps and 

shorten their life. 

Only handle a new heat lamp with soft, dry, clean, 

lint-free cloth or paper. You can wear gloves, cover your fingers or 

wrap the heat lamp until it is installed (so long as you remove all cloth 

or paper when finished).

• The power cable of this product must withstand

 

a minimum 10A

load.

• The main supply and interconnecting cables required for installation

of this unit are not included.

• This unit must be properly grounded.

• The disconnection of the product is achieved by incorporating a

switch in the fixed wiring in accordance with the wiring rules. The

heater must be isolated from the power by means of a disconnection

switch with a contact separation of at least 3mm.

WARNING

: Indicates that injury or death could occur if below 

Warnings 

are not followed.

This unit must be installed to comply with the appropriate council 

regulations and the Australia and New Zealand wiring rules 

AS/NZS3000:2007 or lastest edition thereof.

All wiring must be carried out by a Licensed Electrician in accordance 

with all applicable codes and standards.  

Use this heater only as described in this manual. The manufacturer 

does not recommend any other use as this may cause fire, electric 

shock, or injury to persons. If you have questions, contact the 

manufacturer or local agent.

Make sure the power is off before the installation. 

The heaters glass shield is hot when in use. Do not touch the heat lamp 

and glass shield with any part of your body when in use.

For the purpose of avoiding any dangerous gas leaking into your 

bathroom, the duct vent of the heater must not be laid together with the 

duct vent  of air-fueled water heater or other open-fire appliances into 

the same flue.

The heater is to be installed so that switches and other controls cannot 

be touched by a person in the bath or shower.

This unit should not be installed directly above a shower or bathtub. 

The unit must not be installed in a position where water may splash 

onto the unit.

CAUTION

: Possibility of damage to equipment, installation or premises 

if below 

 

are not followed.

• The appliance is not intended for use by persons (including children)

with reduced physical, sensory or mental capabilities, or lack of

experience and knowledge, unless they have been given supervision or

instruction concerning use of the appliance by a person responsible for

their safety.

• Children should be supervised to ensure that they do not play with the

appliance.

• The appliance shall, under no circumstances, be covered with insulating

material or similar material.

• Regulations concerning the discharge of air have to be fulfilled.

• The unit must not be installed beneath a fixed socket.

• The unit is designed for installation in flat ceilings only. Do not mount it

on a sloping ceiling or a vertical wall.

• Before commencing any cutting, check in the ceiling space that there are

no obstructions such as electrical wiring, hidden utilities or ceiling joists

and that there is sufficient height clearance for the housing. Check that

the electrical wiring can be routed from the wall switches to the mounting

location.

• Joists, beams and rafters shall not be cut or notched to install the

appliance.

!

!

!

!

!

!

!

!

!

a volume equivalent to what is being extracted must be able to 

enter the room. Generally, this air would be drawn under the door 

with a minimum space of 20mm. If the room is airtight, the fan will 

function poorly.

1

2

IR

LED LED

 :Thermal Protector

M:Motor

C:Capacitor

LED: Lamp

IR: Halogen

Remove the screws hidden

behind. Remove the fascia.

Note:

 

 Be careful while removing 

the screws so that the fascia 

does not drop to the ground.

BZSMS158 FAN6577说明书

BY VENTAIR PTY LTD

RIO

PREMIUM HEAT, LIGHT AND EXHAUST

3 1

in

Please use this card as a hole cutting template 470 x 320mm.

Reviews: