background image

1

5

3

2

4

Thank you and congratulations on your purchase of the 
Ventair 3 in1 Bathroom Fan, Heat & Light. Please read these 
instructions carefully before installing and using the product. 
Keep the instructions handy for future reference. 
Electrical wiring must only be done by a licensed electrician 
and a “Certificate of Compliance” must be issued completion 
of the installation.  

LOCATION

The unit must be located and installed in accordance with AS/NZS 

3000 and local building codes and regulations concerning the 

discharge of air have to be fulfilled.The unit can be installed in any 

room that requires direct radiant heating and circulated air flow 

such as bathrooms, ensuites, laundries etc. The unit can be 

installed in flat ceilings with a minimum height of 2 meters. At 

least 250mm height clearance in the ceiling cavity is required to 

ensure sufficient ventilation for moisture to disperse. The unit must 

also be installed at least 400mm away from the walls.Between the 

unit and thermal insulation please also keep 200mm clearance 

when installation.Ensure adequate inlets exist through windows, 

vents or under the door for air flow.

1) Precautions must be taken to avoid the back-flow of gases into 

the room from the open flue of gas or other fuelburning appliances.

2) The distance between the sides of the heater and the sides and 

any adjacent ceiling recessed heater shall not be less than four 

times the minimum distance specified for the distance between 

the sides of the heater and any building element adjacent to it.

3) The switches and other controls of the appliance should be 

installed so that they cannot be touched by a person in the bath or 

shower.

POWER

AC 220-240V, 50Hz electrical supply is required. The unit 
can be connected to a lighting or power circuit if loading 
permits. All electrical work must be carried out in accordance 
with AS/NZS 3000 or latest edition thereof.

320mm x 320mm.

figure 1

figure 2

3. Connect the ducting if required to the 

outer grille of the unit.Insert the unit into the 

square hole being sure to pull the side clips 

inward so that the body can pass through 

the hole without damaging the plaster. 
Rotate the swing clips to hold motor body in 
place(figure 1) then tighten screw to let 
the clip clap onto the ceiling board(figure 2).

ASPEN

PREMIUM HEAT, LIGHT AND EXHAUST

3 1

in

Thank you and congratulations on your purchase of the Manrose 
Aspen 3-in-1 Premium Bathroom Heat, Light and Exhaust. 
Please read these instructions carefully before installing and using 
the product. Keep the instructions handy for future reference.

Reviews: