Technical data
MVHR Installation and User Guide 476930
38
Product fiche
Name:
Vent-Axia
Model ID (Stock Ref.) :
405215 Advance S
405216 Advance SX
476808 Advance Sp LH
476809 Advance Sp RH
SEC Class
A+
SEC Value ('Average')
-43.03
SEC Value ('Warm')
-17.88
SEC Value ('Cold')
-87.71
Label Required? (Yes/No=Out of scope)
Yes
Declared as: RVU or NRVU/UVU or BVU
RVU/BVU
Speed Drive
Variable Speed
Type HRS (Recuperative, Regenerative, None)
Recuperative
Thermal Eff: [ (%), NA(if none)]
89
Max. Flow Rate (m3/h)
378
Max. Power Input (W): (@Max.Flow Rate)
190
LWA: Sound Power Level (dB)
56.0
Ref. Flow Rate (m3/s)
0.07350
Ref. Pressure Diff. (Pa)
50
SPI [W/(m3/h)]
0.25
Control Factor & Control Typology: (CTRL/ Typology)
Control Factor; CTRL
0.65
Control Typology
Local Demand Control
Declared: -Max Internal & External Leakage Rates(%) for BVUs or carry over
(for regenerative heat exchangers only),
-&Ext. Leakage Rates (%) for Ducted UVUs;
<5% Internal, <5% External
Mixing Rate of Non-Ducted BVUs not intended to be equipped with one duct
connection on either supply or extract air side;
N/A
Position and description of visual filter warning for RVUs intended for use with
filters, including text pointing out the importance of regular filter changes for
performance and energy efficiency of the unit
Refer to User Instructions
For UVUs (Instructions Install Regulated Supply/Extract Grilles Façade)
N/A
Internet Address (for Disassembly Instructions)
www.vent-axia.com
Sensitivity p. Var20/-20 Pa: (for Non-Ducted VUs)
N/A
Air Tightness-ID/OD-(m3/h) (for Non-Ducted VUs)
N/A
Annual Electricity Consumption: AEC (kWh/a) pr. m
²
1.75
Annual Heating Saved: AHS (kWh/a) pr. m
²
AHS: Average
46.73
AHS: Warm
21.13
AHS: Cold
91.41
Summary of Contents for 405215 Advance S
Page 17: ...Operating and Monitoring MVHR Installation and User Guide 476930 17...
Page 18: ...Operating and Monitoring MVHR Installation and User Guide 476930 18...
Page 20: ...Operating and Monitoring MVHR Installation and User Guide 476930 20...
Page 21: ...Operating and Monitoring MVHR Installation and User Guide 476930 21...
Page 22: ...Operating and Monitoring MVHR Installation and User Guide 476930 22...
Page 23: ...Operating and Monitoring MVHR Installation and User Guide 476930 23...
Page 24: ...Operating and Monitoring MVHR Installation and User Guide 476930 24...
Page 25: ...Operating and Monitoring MVHR Installation and User Guide 476930 25...
Page 26: ...Operating and Monitoring MVHR Installation and User Guide 476930 26...
Page 27: ...Operating and Monitoring MVHR Installation and User Guide 476930 27...
Page 28: ...Operating and Monitoring MVHR Installation and User Guide 476930 28...