Humidity Operation
To control a MISC output for humidification, place
the MISC1, MISC2, or MISC3 jumper on the term-
inal labeled HUM. This will supply 24VAC to the
selected MISC terminal on the backplate of the
thermostat when the humidity in the home falls
below the setpoint you have chosen. The value for
this setpoint ranges from 0% to 60%. Only one of
the three outputs (MISC1, MISC2, or MISC3) is
required to have this jumper.
For more information
regarding the MISC1, MISC2, and MISC3 outputs
and regarding the Humidity setpoint, please consult
your Owner’s Manual.
The Fan may also be programmed to automatically
energize any time there is a call for humidity.
For
more information regarding energizing the Fan with
Humidification operation, please consult your
thermostat’s Owner’s Manual.
Page 3