background image

6.

M

OUNT THE WALL CONTROL TO THE WALL

P

LUG THE VENTILATION UNIT AND TEST THE

WALL CONTROL OPERATION

.

DECO-TOUCH WALL CONTROL INSTALLATION AND OWNER GUIDE

THIS WALL CONTROL CAN BE USED WITH THE FOLLOWING VENTILATION UNITS:

VENMAR AVS SOLO, DUO, HE, COMPACT, CONSTRUCTO 1.0*, HRV 

AND

ERV EKO 1.5, NOVOFIT, KUBIX HRV PLUS

AND

KUBIX ERV

VÄNEE GOLD SERIES, HE*, 60H*, HRV 

AND

ERV 90H-V ECM, NOVO+, VIGÖR HRV PLUS

AND

VIGÖR ERV

IT IS NOT COMPATIBLE WITH OTHER VENTILATION UNITS.

*CONSTRUCTO 1.0 AND VÄNEE 60H BUILT IN AUGUST 2008 AND LATER, AND VÄNEE HE BUILT IN JULY 2006 OR LATER. THE DATE CODE ON

THE UNIT IS PART OF ITS 13-DIGIT SERIAL NUMBER. FOR EXAMPLE, THE SERIAL NUMBER XXXX

0708

XXXXX, WHERE 07 IS THE YEAR AND

08 THE MONTH (AUGUST); THE DATE CODE IS ALWAYS THE FIFTH, SIXTH, SEVENTH AND EIGHTH DIGITS.

A

LWAYS DISCONNECT THE UNIT BEFORE MAKING ANY CONNECTIONS

. F

AILURE TO DISCONNECT POWER COULD RESULT IN ELECTRIC SHOCK OR DAMAGE

TO THE WALL CONTROL OR ELECTRONIC MODULE INSIDE THE UNIT

.

WARNING

!

F

AILURE TO COMPLY WITH THE FOLLOWING CAN CAUSE ERRATIC OPERATION OF THE UNIT

:

• N

EVER INSTALL MORE THAN ONE MAIN WALL CONTROL PER VENTILATION UNIT

.

• K

EEP CONTROL LOW VOLTAGE WIRING AT LEAST

FOOT

(305 

MM

AWAY FROM MOTORS

LIGHTING BALLAST

LIGHT DIMMING CIRCUIT AND POWER

DISTRIBUTION PANEL

. D

O NOT ROUTE CONTROL WIRING ALONGSIDE HOUSE POWER WIRING

.

• E

NSURE THE WIRES ARE SECURELY CONNECTED

.

CAUTION

W

ALL

C

ONTROL

I

NSTALLATION

5.

S

TRIP THE END OF THE CABLE TO ACCESS THE

WIRES

. S

TRIP THE END OF EACH WIRE

U

SING A SMALL FLAT BLADE SCREWDRIVER

CONNECT EACH WIRE TO ITS CORRESPONDING
TERMINAL ON THE BACK OF THE WALL
CONTROL

: YELLOW 

WIRE TO

“Y”, RED 

WIRE

TO

“R”, GREEN 

WIRE TO

“G” 

AND

BLACK 

WIRE TO

“B”.

Y

B

G

R

VE0243

2.

C

UT A

7

/

8

” 

X

1 ³/

8

” 

HOLE IN WALL AT A

CONVENIENT LOCATION FOR THE WALL CONTROL

.

R

OUTE THE CABLE FROM THE UNIT TO THIS

HOLE

.

NOTE:D

IMENSIONS SHOWN ARE FOR AN

INSTALLATION WITHOUT WALL BOX

.

1.

U

NPLUG THE VENTILATION UNIT FROM POWER SOURCE

.

VC0115

3.

T

EMPORARILY PLACE THE SWITCH OVER THE

HOLE AND MARK BOTH MOUNTING SCREW
HOLE POSITIONS

.

4.

R

EMOVE THE SWITCH

DRILL BOTH SCREW

HOLES

(Ø 3/16”) 

IN WALL AND INSERT WALL

ANCHORS

(

INCLUDED

).

VC0116A

Ø 3/16”, typ. 

OR

W

ALL

C

ONTROL

U

SE

B

ACKLIGHT

I

F THE BACKLIGHT IS NOT ILLUMINATED

THE FIRST BUTTON PRESSED

(

NO MATTER

WHICH BUTTON

SHALL TURN ON THE BACKLIGHT

. T

HE BACKLIGHT REMAINS ILLUMINATED

FOR

10 

SECONDS AFTER THE LAST BUTTON PRESSED

.

O

PERATING

M

ODES

OFF

P

UT THE UNIT ON STAND

-

BY MODE

SO IT WILL ONLY RESPOND TO

OVERRIDE WALL CONTROLS

(

IF PRESENT

). O

N

LCD 

SCREEN

ONLY THE

H

OUSE

IS VISIBLE

SHOWING THE

CONTROL

IS

POWERED

ON

T

HIS IS THE FACTORY DEFAULT MODE

.

RECIRC

A

IR IS RECIRCULATED INSIDE THE HOUSE AT HIGH SPEED

.

20 

MIN

/

H

T

HE VENTILATION UNIT EXCHANGES AIR INTERMITTENTLY ON A ONE HOUR

CYCLE AS FOLLOWS

: OFF 

FOR

40 

MIN

. (

OR RECIRCULATION ON

HIGH SPEED FOR

40 

MIN

., 

SEE NEXT

S

ECTION ON BACK PAGE

AND

THEN EXCHANGE AIR DURING

20 

MIN

ON LOW SPEED

. R

EPEAT CYCLE

AFTER THE

20 

MIN

OF AIR EXCHANGE

.

MIN

A

IR IS EXCHANGED WITH THE OUTSIDE ON LOW SPEED

.

MAX

A

IR IS EXCHANGED WITH THE OUTSIDE ON HIGH SPEED

.

O

PERATING

M

ODES

(

CONT

D

)

T

O CHANGE THE OPERATION MODE OF THE VENTILATION UNIT

PRESS

THE

UP 

OR

DOWN 

ARROW BUTTON

. O

PERATING MODE LABEL WILL

THEN SCROLL UP OR DOWN ON

LCD 

SCREEN

.

09947 

REV

. B

Reviews: