INSTALLATION INSTRUCTIONS
AND USER GUIDE
V
enmar
models
B
roan
EVO5 700 HRV HEPA
EVO5 500 HRV
HRV 7.1 HEPA
HRV 5.1
r
esidential
indoor
use
only
VQ0009
!
READ AND SAVE THESE INSTRUCTIONS
20846 rev. E
VB0313
VB0312
VB0311
VB0310
Page 1: ...RUCTIONS AND USER GUIDE Venmar models Broan models EVO5 700 HRV HEPA EVO5 500 HRV HRV 7 1 HEPA HRV 5 1 Residential indoor use only VQ0009 VQ0009 READ AND SAVE THESE INSTRUCTIONS 20846 rev E VB0313 VB0...
Page 2: ...e plugged into a mating 3 prong grounding receptacle grounded in accordance with the national electrical code and local codes and ordinances Do not remove the ground prong Do not use an extension cord...
Page 3: ...rts 11 3 7 Installing Dual Exterior Hood 11 12 3 7 1 Assembling Dual Exterior Hood 11 3 7 2 Locating Dual Exterior Hood 11 3 7 3 Connecting Tandem Transition to Dual Exterior Hood 12 3 8 Connecting th...
Page 4: ...evel Homes with more than one level require at least one exhaust register at the highest level See figure at right 1 2 Central Draw Point Connection to a forced air system VH0089 Stale air coming from...
Page 5: ...nsition VD0118A 8 222 mm 9 248 mm The joist opening needed to install theTandem tansition included in ISKV1000 and ISKB1000 installation kits must be 9 248 mm minimum Also the maximumheightoftheTandem...
Page 6: ...stallation date on the HEPA filter frame for future reference see illustration at right TO P DES SU S FR O N T AV A N T Ins tal dat e Da te d in sta l _ _ _ _ _ _ _ _ 212 93 F R O N T A V A N T In st...
Page 7: ...minimum Do not ventilate crawl spaces or cold rooms Do not attempt to recover the exhaust air from a dryer or a range hood This would cause clogging of the filters and recovery module If the house ha...
Page 8: ...level to ensure the greatest possible air circulation Keep in mind that the fresh air diffuser must be located as far as possible from the stale air diffuser If desired you can install another diffuse...
Page 9: ...orresponding port then do the same for the exhaust air to building duct and port See illustration at right NOTE Use an insulated duct not included if the duct will have to go through a space where it...
Page 10: ...will need two exterior hoods instead of one In this case do not use the Tandem transition go to point 3 6 2 and refer to the optional single hood enclosed instructions For each duct pull back the ins...
Page 11: ...around the joint Compressed insulation loses its insulation properties and causes water dripping due to condensation on the exterior surface of the duct CAUTION 3 7 Installing Dual Exterior Hood Exte...
Page 12: ...de duct will be located on top CAUTION VD0085 Xmas tree pin Join the end of the Tandem transition to the rear of the exterior backplate Secure with 2 Xmas tree pins and seal properly with duct tape Th...
Page 13: ...of the LED will show on which defrost cycle the unit is set NOTE No command will be taken until the unit is fully booted 4 2 Defrost Cycles Five seconds after the booting sequence is done the LED 2 wi...
Page 14: ...tic operation of the unit and or the wall control Never install more than one main wall control per ventilation unit Keep control low voltage wiring at least 1 foot 305 mm away from motors lighting ba...
Page 15: ...artment interface Plug the unit Usetheterminalconnectorincludedintheinstallationkittoperformtheelectricalconnection for main and optional wall controls Check if all wires are correctly inserted in the...
Page 16: ...n Modes 4 6 Main Wall Control Use When the wall control is ON press the MODE key to choose the operation mode of the ventilation unit Operating Mode label will then appear on LCD screen AUTO ECO CONT...
Page 17: ...this particular case the unit will get back to the mode chosen before TURBO mode VQ0067 When the wall control is ON no matter the operation mode pressing on TURBO key will turn the unit on air exchang...
Page 18: ...d Temperature Unit NOTE Prior to perform this setting the wall control must be ON VQ0067 Press and hold on ECO key during 4 seconds NOTE To get back to C for temperature display repeat the complete pr...
Page 19: ...e 25 13 will flash factory set value OR according to the displayed temperature unit chosen To enter a lower value press on ECO key to enter a higher value press the TURBO key VQ0087 OR VQ0088 4 sec VQ...
Page 20: ...hen the wrench icon appears on wall control screen perform the required maintenance according to the unit model Maintenance table for EVO5 500 HRV and HRV 5 1 units Appearance Maintenance Type First T...
Page 21: ...wall of the unit with a damp cloth then wipe with a dry one Remove dust on core using a vacuum cleaner with a soft brush attachment Wash both core filters under hot water with mild soap Rinse thoroug...
Page 22: ...water and mild soap dishwashing liquid Rinse carefully drain off water and reinstall with its filters For EVO5 700 HRV HEPA and HRV 7 1 HEPA units only The heat recovery core must be reinstalled BEFO...
Page 23: ...cold at the air supply grille on cold season Check if the exterior hood is not blocked specifically the top grille Set the unit in AUTO or ECO mode See Control section 4 6 1 Operation modes on pages 1...
Page 24: ...enuine replacement parts only The manufacturer genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards and maintai...
Page 25: ...SATION 20846 r v E Utilisation r sidentielle int rieure seulement VQ0009 VQ0009 VEUILLEZ LIRE ET CONSERVER CES DIRECTIVES Mod les Venmar Mod les Broan EVO5 700 HRV HEPA EVO5 500 HRV HRV 7 1 HEPA HRV 5...
Page 26: ...nform ment au code national d lectricit ainsi qu aux codes et r glements locaux Ne pas enlever la broche pour la mise la terre Ne pas utiliser de rallonge lectrique 8 Ne pas installer dans une aire de...
Page 27: ...ext rieure double 11 12 3 7 1 Assemblage de la bouche ext rieure double 11 3 7 2 Emplacement de la bouche ext rieure double 11 3 7 3 Raccordement de la transition Tandem la bouche ext rieure double 1...
Page 28: ...l par syst me Ne raccorder l appareil aucun conduit de distribution de syst me air puls ATTENTION Ne raccorder l appareil aucun conduit de distribution de syst me air puls ATTENTION Les illustrations...
Page 29: ...n Tandem VD0118F 8 po 222 mm 9 po 248 mm LadistancerequiseentrelessolivespourlatransitionTandem inclusedansles trousses d installation ISKV1000 et ISKB1000 est d au moins 9 po 248 mm La hauteur maxima...
Page 30: ...e d in sta l _ _ _ _ _ _ _ _ 212 93 F R O N T A V A N T In st al da te D at e d in st al _ _ _ _ _ _ _ _ VD0309 V rifier si l ext rieur de l appareil n a subi aucun dommage S assurer que la porte les...
Page 31: ...simple possible avec un minimum de coudes et de raccords La longueur des conduits isol s doit tre r duite son minimum Ne pas ventiler les vides sanitaires ni les chambres froides Ne pas tenter de r cu...
Page 32: ...Installer le diffuseur au plafond OU sur un mur int rieur une distance de 6 po 12 po 152 mm 305 mm du plafond L air frais circulera travers la pi ce et se m langera l air ambiant assurant ainsi un re...
Page 33: ...tr me temp rature ex un grenier non chauff dans une r gion nordique ou un grenier non climatis dans une r gion chaude Aussi si vous pr voyez arr ter l appareil pour plus de 12 heures nous recommandons...
Page 34: ...bouche double Dans ce cas ne pas utiliser la transition Tandem passer au point 3 6 2 et vous r f rer aux directives incluses avec la bouche ext rieure simple optionnelle Pour chaque conduit tirer sur...
Page 35: ...du joint Un isolant comprim perd ses propri t s isolantes et provoque la formation de gouttes condensation sur la surface ext rieure du conduit ATTENTION 3 7 Installation de la bouche ext rieure doub...
Page 36: ...vici soit situ sur le dessus ATTENTION VD0085 Goupille de retenue Relier l extr mit de la transition Tandem l arri re de la plaque de la bouche ext rieure Fixer l aide de 2 goupilles de retenue et sce...
Page 37: ...de d givrage programm dans l appareil NOTE L appareil ne peut r pondre aux commandes tant que la s quence de d marrage de l appareil n est pas compl t e S il survient un probl me lors du fonctionnemen...
Page 38: ...entra ner le fonctionnement erratique de la commande murale Ne jamais installer plus d une commande murale principale par appareil Tenir le c blage basse tension de la commande une distance d au moin...
Page 39: ...bornier inclus dans le kit d installation pour effectuer le branchement de la commande principale optionnelle ainsi que de la commande auxiliaire optionnelle S assurer que les fils soient ins r s cor...
Page 40: ...nnement 4 6 Utilisation de la commande murale principale Lorsque la commande murale est en MARCHE appuyer sur la touche MODE pour choisir le mode de fonctionnement de l appareil de ventilation Le nom...
Page 41: ...es autres modes l cran Appuyer une autre fois pour sortir du mode ECO et revenir au mode de fonctionnement pr c dent Sauf s il tait en mode TURBO dans ce cas particulier l appareil retournera au mode...
Page 42: ...F clignotera l cran un moment pour montrer qu il est maintenant la nouvelle unit de temp rature puis restera l cran L unit de temp rature affich e est pr r gl e en usine en degr s Celcius C mais si d...
Page 43: ...airet Cext Fext apparaissent l cranet 25 13 clignote valeur pr r gl e OU selon l unit de temp rature d affichage choisie NOTE Pouracc derdirectement au r glage de la valeur maximalesanschanger la mini...
Page 44: ...gulier Troisi me fois R gulier Quatri me fois Annuel VQ0084 5 1 Cycles d entretien Ces appareils n cessitent des entretiens r guliers et annuels Lorsque la cl appara t l cran de la commande murale eff...
Page 45: ...l appareil avec un linge humide puis les essuyer avec un linge sec Enlever la poussi re du noyau l aide d un aspirateur muni d une brosse poils doux Laver les deux filtres de noyau avec de l eau chau...
Page 46: ...OTE Apr s un d lai de 20 secondes pour la s quence de d marrage l appareil reviendra son fonctionnement pr c dent R initialiser la commande murale VQ0083 5 2 Entretien r gulier suite 5 3 Entretien ann...
Page 47: ...ent en pages 16 et 17 5 Air trop froid la grille de distribution en saison froide V rifier si la bouche ext rieure n est pas obstru e surtout la grille sup rieure R gler l appareil en mode AUTO ou ECO...
Page 48: ...t sp cialement con ues pour satisfaire toutes les normes de certification de s curit applicables Leur remplacement par des pi ces ne provenant pas du manufacturier pourrait ne pas assurer la s curit d...