background image

5

CONNECTION FROM BEHIND



Choose a location under the cabinet for the V600W 
VacuSweep inlet valve so that it can be connected 
to the central vacuum tube. Measure distance (X) 
between the kickplate face and the inside edge 
of the cabinet. Then, add 2¾” to the measured 
distance. Refer to figure 

. Measure out the new 

distance (X + 2¾”) from the cabinet door, to the 
reference mark.



Drill a small reference hole straight down through 
to the basement. Refer to figure 

. Locate the 

reference hole in the basement and verify that there 
are no obstructions.



Using a reciprocating saw, cut an access hole in the 
floor under the cabinet and approximately 8” behind 
the location of the V600W VacuSweep inlet valve 
reference hole so that the V600W VacuSweep inlet 
valve can be connected to vacuum tube by reaching 
through the access hole. Refer to figure 

.

 

Using the reference hole as a center, cut a 
2 ³/

8

” H x 6 

5

/

8

” W rough opening in the kickplate 

face. Refer to figure 

.

 Insert a coupling (part no. V127) onto the rear of the 

housing. 

DO NOT GLUE

 this connection (Designed 

for friction fit). Refer to figure 

. Make the terminal 

connections to the V600W VacuSweep inlet valve by 
sliding the low-voltage wire into wire clips. Turn the 
power to the vacuum unit ON to test the connection. 
After successful completion of the test, turn power to 
the vacuum unit OFF. Insert the V600W VacuSweep 
inlet valve into the cabinet base and tube.

  With the door in an open position, secure the V600W 

VacuSweep inlet valve to the cabinet base using 
no. 6 screws. Refer to figure 

Ensure that the 

spring on the electrical connector has 1/8” 
clearance to rough opening.

 From the basement 

reach through the access hole and glue a section 
of 2” central vacuum tube to the coupling. Continue 
with remainder of central vacuum connections.

V600W VACUSWEEP® INLET VALVE INSTALLATION (

CONT

'

D

)

AD0046A

C

ABINET

K

ICKPLATE

C

ABINET

C

ABINET

DOOR

R

EFERENCE

M

ARK

2¾”

X

S

UBFLOOR

J

OIST

J

OIST

(X) + (2¾”)

R

EFERENCE

MARK

S

UBFLOOR

R

EFERENCE

 

HOLE

SEEN

 

FROM

 

BASEMENT

C

ABINET

DOOR

R

EFERENCE

HOLE

8”

C

UT

 8” 

ACCESS

 

HOLE

 

BEHIND

 

REFERENCE

 

HOLE

8” 

ACCESS

 

HOLE

J

OIST

C

UT

 

A

 23/

8

” H 

X

 6

5

/

8

” W

ROUGH

 

OPENING

 

USING

 

THE

REFERENCE

 

HOLE

 

AS

 

CENTER

2” 

CENTRAL

VAC

 

PIPE

C

OUPLING

D

O

 

NOT

 

GLUE

THIS

 

CONNECTION

V

ACU

S

WEEP

®

I

NLET

 

VALVE

G

LUE

 

THIS

CONNECTION

(

COUPLING

/

PIPE

)

T

ERMINAL

 

CONNECTIONS

V

ACU

S

WEEP

®

I

NLET

 

VALVE

X

 

NO

. 6

SCREWS

D

O

 

NOT

 

GLUE

THIS

 

CONNECTION

8”

ACCESS

HOLE

T

ERMINAL

WIRES

G

LUE

 

THIS

CONNECTION

C

OUPLING

2” 

CENTRAL

VAC

 

PIPE

Summary of Contents for 500VF

Page 1: ...SIDENTIAL USE ONLY REGISTER YOUR PRODUCT ONLINE AT WWW VENMAR CA 30042507B AB0039 CENTRAL VACUUM POWER UNITS MODELS SFDB DK SFDB DL AND SFDB DM VENMAR VENTILATION ULC DRUMMONDVILLE QU BEC WWW VENMAR C...

Page 2: ...r loose clothing fingers and all parts of body away from openings and moving parts 8 Turn off all controls before unplugging 9 Use extra care when cleaning on stairs 10 Do not handle plug or appliance...

Page 3: ...ubing and the outside of the plastic tubing or mounting plate tubing ring Twist both pieces while joining them to evenly spread the glue Allow 5 minutes for the cement to set in flexible tubing SECURE...

Page 4: ...it OFF Wrap a piece of wire string around the pipe Using the wire string to temporarily hold the pipe and elbow in place insert the V600W VacuSweep inlet valve into the cabinet base and elbow DO NOT G...

Page 5: ...he V600W VacuSweep inlet valve by sliding the low voltage wire into wire clips Turn the power to the vacuum unit ON to test the connection After successful completion of the test turn power to the vac...

Page 6: ...2XS ontoasectionof2 centralvacuum tube Make the terminal connections to the V600W VacuSweep inlet valve by sliding the low voltage wire into wire clips Turn the power to the vacuum unit ON to test the...

Page 7: ...e the screw tightening the bag adapter and intake elbow junction Disassemble the bag adapter from the intake elbow and set aside with its screw and nut Allunits Disassemble the intake elbow from the b...

Page 8: ...ing bracket on the wall through upper and lower mounting holes Hang power unit onto wall mounting bracket Ensure the back brackets of the power unit are engaged with corresponding wall bracket fingers...

Page 9: ...ic current to reduce the risk of electric shock This appliance is equipped with a cord having an equipment grounding conductor and grounding plug The plug must be plugged into an appropriate outlet th...

Page 10: ...emove the disposable bag release both latches on sides of the unit by pulling out and then pushing up Remove the pail from unit Grasp the edges of the bag collar and pull down The bag will slide off e...

Page 11: ...tor foam safety filter located at the top of the vacuum chamber provides protection against dirt being pulled into the motor if the disposable bag or permanent filter should accidentally be torn This...

Page 12: ...and over the opposite end of the hose When you can feel the suction increase hold your hand over the hose end for a few seconds and then quickly remove your hand This procedure repeated several times...

Page 13: ...epot for all replacement parts and repairs 4 11 7 12 KEY NO PART NO DESCRIPTION 500VF 600VF 650VF 1 S10941410 650VF TOP CAP ASSEMBLY INCLUDING ITEM 5 UPPER PART 1 S10941412 500VF AND 600VF TOP CAP ASS...

Page 14: ...any implied warranty is limited to the period as specified for the express warranty VENMARVENTILATION S OBLIGATIONTO REPAIR OR REPLACE ATVENMARVENTILATION S OPTION SHALL BETHE PURCHASER S SOLE AND EXC...

Reviews: