background image

venini.com.au

user  

manual

2 year  

warranty

VGF60 

60cm  

gas  

cooktop

Summary of Contents for VGF60

Page 1: ...venini com au user manual 2 year warranty VGF60 60cm gas cooktop...

Page 2: ......

Page 3: ...best potential or tips on cleaning please feel free to call us on the above number It is important that you read through the following instruction manual thoroughly to become familiar with the instal...

Page 4: ...ooktop Installation and User manual Content Safety instructions 3 Product description 4 Installation 6 Start using your appliance 9 Maintenance and troubleshooting 11 Warranty 14 GHS604A G2CI GHS604B...

Page 5: ...l sensory or mental capabilities or their inexperience or ignorance are not able to use the device safely should not use this device without supervision or instruction by a responsible person This app...

Page 6: ...er connecting to gas check for leaks using soapy solution never a naked flame Where a flexible hose assembly is used ensure it is approved to AS NZS 1869 Class B 10mm diameter and no more than 1 0metr...

Page 7: ...2 GHS604B G2CI 1R 2SR 1A With 2 types for option Front LPG 27 5MJ h NG 26 0MJ h 3 GH614AS G2CI 1W 2SR 1A With 2 types for option Right LPG 30 5MJ h NG 29 5MJ h 4 GH614BS G2CI 1R 2SR 1A With 2 types fo...

Page 8: ...lip 4 sets Screws ST4 2x24 4 pcs LPG Injectors 4 pcs Elbow Washers 1 Elbow 3 washers Natural gas regulator 1 Technical Specifications Model Product Dimensions h x w x d mm Cut out Size w x d mm App x...

Page 9: ...mm Horizontal surfaces adjacent the hob less than or equal to the hob height Ensure there is sufficient clearance to fit the regulator and or flexible hose connection with the hotplate in the install...

Page 10: ...ame for correct operation If burner is placed correctly it will not rotate on its supports The Triple Ring Wok burner diagrams below does not fit over the igniter or thermocouple but must be placed on...

Page 11: ...st be restrained from accidental contact with the flue outlet of an under bench oven This hose assembly shall be suitable for connection to a fixed consumer piping outlet located as follows Hotplates...

Page 12: ...rer or agent as required ADJUSTED FOR NATURAL GAS 1 0kPa ADJUSTED FOR ULPG 2 75KPa NOZZLES DIAMETER mm Gas consumption MJ h NOZZLES DIAMETER mm Gas consumption MJ h WOK 1 70 13 0 WOK 0 98 13 0 Rapid 1...

Page 13: ...er waiting 1 minute for gas to disperse If problems with burner lighting persist refer to the TROUBLESHOOTING section of these instructions If power is not available light a match or similar then turn...

Page 14: ...Note S Ignition pin T Thermocouple Use a cotton bud tooth brush or some other item to clean out any incrustations or dirt from the four holes marked H The spark gas is 4 6mm Replace burners and ensure...

Page 15: ...circuit breaker Loose sparker cable Call authorised representative Burner not aligned properly Remove and re fit burner Burner not lighting when spark ignition working Gas supply off Check gas supply...

Page 16: ...Distributed by Home Appliances Pty Ltd 20 Carlotta Street Artarmon NSW 2064 Tel 02 9958 3111 Fax 02 9958 3555 Email info hapl com au Website www hapl com au...